Safety and Efficacy of Sequential Intracorneal Ring Segment Implantation and Cross-linking in Pediatric Keratoconus
To evaluate the safety and visual outcome of intracorneal ring segment (ICRS) implantation followed by cross-linking in pediatric keratoconus patients. Retrospective interventional case series. This retrospective study included pediatric patients (aged ≤14 years) with keratoconus and poor corrected...
Gespeichert in:
Veröffentlicht in: | American journal of ophthalmology 2017-06, Vol.178, p.51-57 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To evaluate the safety and visual outcome of intracorneal ring segment (ICRS) implantation followed by cross-linking in pediatric keratoconus patients.
Retrospective interventional case series.
This retrospective study included pediatric patients (aged ≤14 years) with keratoconus and poor corrected distance visual acuity (CDVA) that underwent ICRS implantation and cross-linking (CXL). ICRS were inserted under topical anesthesia after creating a corneal tunnel with a femtosecond laser. Cross-linking was performed 1 month subsequently. Records were reviewed and data collected preoperatively and at 6 months, 1 year, 2 years, and 4 years postoperatively.
Twelve patients (17 eyes; 10 male, 2 female) aged 9–14 years (mean age 12.3 years) received ICRS implantation followed by CXL. Follow-up times ranged from 6 months to 4 years after surgery. At the 6-month follow-up all eyes were evaluated; at the 1-year, 2-year, and 4-year follow-up 11, 10, and 7 eyes were evaluated, respectively. At the 6-month follow-up, mean CDVA in comparison to preoperative levels improved significantly (P = .001) from 0.30 ± 0.19 logMAR to 0.12 ± 0.1 logMAR; mean uncorrected distance visual acuity (UDVA) also improved significantly from 0.90 ± 0.50 logMAR to 0.43 ± 0.31 logMAR. A significant decrease in both keratometry readings and spherical equivalent (from −4.0 to −1.56 diopters) was also noted after ICRS insertion. At the 1-year, 2-year, and 4-year follow-up refractive values remained relatively stable in comparison to the 6-month follow-up, except for a minor but significant improvement in cylinder and, at 4 years, in UDVA. All patients tolerated the surgery well and no intraoperative or postoperative complications were reported, except for 1 ring segment that had to be removed after 2 years owing to vascularization and corneal thinning.
ICRS implantation is a safe and effective procedure for visual rehabilitation in children with keratoconus and poor CDVA. |
---|---|
ISSN: | 0002-9394 1879-1891 |
DOI: | 10.1016/j.ajo.2017.03.016 |