Effect of Pore Size on Partial Discharge in Ultra-High Voltage Ceramic Capacitors

Effect of pore size on partial discharge in ultra-high voltage ceramic capacitors was investigated. Nondestructive ultrasonic detection was used to measure pore size in ceramics while the partial discharge characteristics were evaluated by a discharge detector. It is found that the partial discharge...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Key Engineering Materials 2017, Vol.726, p.235-239
Hauptverfasser: Chen, J.J., Hong, Ying Lun, Huang, Jin Tao, Zhuang, Jian Yong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Effect of pore size on partial discharge in ultra-high voltage ceramic capacitors was investigated. Nondestructive ultrasonic detection was used to measure pore size in ceramics while the partial discharge characteristics were evaluated by a discharge detector. It is found that the partial discharge quantity and discharge inception voltage greatly depend on the size of the biggest pore in the ceramic. The partial discharge characteristics become worse when the inner pore is bigger. Possible explanation is discussed based on an equivalent circuit simulating the capacitor with one large pore.
ISSN:1013-9826
1662-9795
1662-9795
DOI:10.4028/www.scientific.net/KEM.726.235