Self-tuning interfacial architecture for Estradiol detection by surface plasmon resonance biosensor

This study reports the operation principles for reusable SPR biosensors utilizing nanoscale-specific electrostatic levitation phenomena in their sensitive layer design. Functional macromolecular building blocks localized near the “charged” surface by a variety of weak electrostatic interactions crea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biosensors & bioelectronics 2017-04, Vol.90, p.91-95
Hauptverfasser: Boltovets, Praskoviya, Shinkaruk, Svitlana, Vellutini, Luc, Snopok, Borys
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study reports the operation principles for reusable SPR biosensors utilizing nanoscale-specific electrostatic levitation phenomena in their sensitive layer design. Functional macromolecular building blocks localized near the “charged” surface by a variety of weak electrostatic interactions create a flexible and structurally variable architecture. A proof-of-concept is demonstrated by an immunospecific detection of 17β-Estradiol (E2) following the competitive inhibition format. The sensing interfacial architecture is based on the BSA-E2 conjugate within the BSA matrix immobilized on the “charged” (as a result of guanidine thiocyanate treatment) gold surface at pH 5.0. Kinetic analysis for different E2 concentrations shows that using parameter β of the stretched exponential function ~(1-exp(-(t/τ)β) as an analyte-specific response measure allows one to substantially decrease the low detection limit (down to 10−3ng/ml) and increase the dynamic range (10−3–103ng/ml) of the SPR biosensor. Finally, it's concluded that the created interfacial architecture is a typical complex system, where SPR response is formed by the stochastic interactions within the whole variety of processes in the system. The E2 addition destroys the uniformity of the reaction space (where an interaction of the antibody (Ab) and the analog of E2 in the self-tuneable matrix takes place) by the redistribution of the immunospecific complexes Ab(E2)x (x=0, 1, 2) dependent on E2 concentration. Binding dynamics changes are reflected in the values of β which summarize in compact form all “hidden” information specific for the evolving distributed interfacial system. •The electrostatic levitation is a new concept for self-tuning architectures design.•Flexibility and variability of the sensing layer is needed for successful biosensing.•Nonexponential relaxation is a universal way to characterize complex systems kinetics.
ISSN:0956-5663
1873-4235
DOI:10.1016/j.bios.2016.11.017