Occupational exposure to fluorinated hydrocarbons during refrigeration repair work
This study describes refrigeration repair workers' occupational exposures to halogenated refrigerants, focusing on difluorochloromethane (HCFC 22), tetrafluoroethane (HFC 134a) and a mixture of tri-, tetra- and pentafluoroethane (R404A) in 30 work operations. Unlike earlier reported studies, th...
Gespeichert in:
Veröffentlicht in: | Journal of environmental monitoring 2003-04, Vol.5 (2), p.236-240 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study describes refrigeration repair workers' occupational exposures to halogenated refrigerants, focusing on difluorochloromethane (HCFC 22), tetrafluoroethane (HFC 134a) and a mixture of tri-, tetra- and pentafluoroethane (R404A) in 30 work operations. Unlike earlier reported studies, the present study includes working procedures involving welding in order to measure possible occupational exposure to decomposition products. The measurements included hydrogen fluoride (HF), hydrogen chloride (HCl), phosgene (COCl2) and volatile organic compounds (VOC). The exposures were assessed during work operations on small-scale cooling installations like refrigerators and freezers. The repair workers' occupational exposures to refrigerants were moderate, and the major part of the exposures were associated with specific working procedures lasting for relatively short periods of time ( |
---|---|