Humeral head sizing using extra-articular landmarks on conventional radiographs

Purpose Proper humeral head (HH) sizing is critical to success in anatomic shoulder replacement for management of glenohumeral arthritis. In this study, we evaluate the accuracy and reliability of using non-articular landmarks on conventional radiographs for HH templating. Methods Anatomic HH replac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgical and radiologic anatomy (English ed.) 2017-09, Vol.39 (9), p.999-1004
Hauptverfasser: Savin, David D., Piponov, Hristo, Goldstein, Jeffrey, Youderian, Ari R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Proper humeral head (HH) sizing is critical to success in anatomic shoulder replacement for management of glenohumeral arthritis. In this study, we evaluate the accuracy and reliability of using non-articular landmarks on conventional radiographs for HH templating. Methods Anatomic HH replacement was performed on five non-arthritic shoulders, from fresh adult cadavers. Pre-operative and post-operative radiographs and 3-D CT scans were obtained. Humeral head size was determined using the articular surface and three extra-articular landmarks (inner aspect of the lateral cortex, the medial footprint of the rotator cuff, and the medial calcar). Two independent observers performed each measurement twice to evaluate reliability. The accuracy was assessed by subtracting the mean values from both the 3D-CT and the implanted HH size measurements. Results Intraclass correlation coefficient for Observer 1 and 2 for the three-point method showed excellent test–retest reliability 0.996 (95% CI 0.994–0.998) and 0.997 (95% CI 0.995–0.998), respectively. Inter-observer ICC for the three-point method was 0.996 (95% CI 0.994–0.997) showing high level of precision. The three-point method was overestimating the size of the HH (to 3D-CT) with 0.46 ± 0.61 mm on average. The three-point method predicted the size of the HH within 1 mm of the implanted head size showing very high accuracy. The center of rotation (COR) for the three-point method was within 1.34 mm of the (COR) of the articular surface. Conclusion The three-point measuring technique using conventional radiographs may be useful to predict the HH size using extra-articular landmarks within a small margin of error. This method is simple, cost effective and has high level of precision. Level of evidence Basic Science Study; Anatomic and Imaging Study.
ISSN:0930-1038
1279-8517
DOI:10.1007/s00276-017-1833-z