Recognizing subtle near-occlusion in carotid stenosis patients: a computed tomography angiographic study
Introduction Near-occlusion of the internal carotid artery (ICA) is a significant luminal diameter (LD) reduction beyond a tight atherosclerotic carotid stenosis (CS). Recognition of even subtle near-occlusions is essential to prevent underestimation of the stenosis degree. Our goal was to investiga...
Gespeichert in:
Veröffentlicht in: | Neuroradiology 2017-04, Vol.59 (4), p.353-359 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
Near-occlusion of the internal carotid artery (ICA) is a significant luminal diameter (LD) reduction beyond a tight atherosclerotic carotid stenosis (CS). Recognition of even subtle near-occlusions is essential to prevent underestimation of the stenosis degree. Our goal was to investigate the prevalence of near-occlusion among CS patients using a single standard criterion to facilitate its recognition, even when distal ICA LD reduction is not visually evident in computed tomography angiography (CTA).
Methods
We analysed carotid artery CTAs of 467 patients with moderate-to-severe CS scheduled for endarterectomy. We performed measurements of the bilateral distal ICA LDs from thin axial source images and utilized a 1.0 mm intra-individual side-to-side distal ICA LD difference to distinguish near-occlusions, based on a previous study, aware of the vagaries of measurement. For analysis stratification, we excluded cases with significant carotid pathology affecting LD measurements.
Results
We discovered 126 near-occlusions fulfilling our criterion of ipsilateral near-occlusion: the mean LD side-to-side difference (mm) with 95% confidence interval being 1.8 (1.6, 1.9) and a standard deviation of 0.8 mm. Among the 233 cases not meeting our near-occlusion criterion, we found 140 moderate (50–69%) and 93 severe (70–99%) ipsilateral stenoses.
Conclusion
The utilization of 1.0 mm cut-off value for the intra-individual distal ICA LD side-to-side difference to distinguish atherosclerotic ICA near-occlusion leads to a relatively high incidence of near-occlusion. In CTA, recently suggested to be used for near-occlusion diagnosis, a discriminatory 1.0 mm cut-off value could function as a pragmatic tool to enhance the detection of even subtle near-occlusions. |
---|---|
ISSN: | 0028-3940 1432-1920 |
DOI: | 10.1007/s00234-017-1791-5 |