Successful management of antibody-mediated rejection after cardiac transplantation in a patient supported by a left ventricular assist device for more than 3 years

Due to donor shortage, patients with refractory heart failure need to be supported on mechanical circulatory support (MCS). Critically, patients undergo several deployments of MCS in stages inevitably requiring blood products transfusion. MCSs per se along with blood products can trigger immune allo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:General thoracic and cardiovascular surgery 2017-12, Vol.65 (12), p.710-712
Hauptverfasser: Akiyama, Masatoshi, Takahara, Shingo, Kawatsu, Satoshi, Endo, Yoichi, Fujiwara, Junko, Adachi, Osamu, Kumagai, Kiichiro, Kawamoto, Shunsuke, Saiki, Yoshikatsu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Due to donor shortage, patients with refractory heart failure need to be supported on mechanical circulatory support (MCS). Critically, patients undergo several deployments of MCS in stages inevitably requiring blood products transfusion. MCSs per se along with blood products can trigger immune allosensitization. Antibody-mediated rejection (AMR) is associated with significant mortality after heart transplantation. Here, we present the case with high panel-reactive antibody over 95% who developed AMR early after heart transplantation. This life-threatening complication was successfully treated with multi-modal treatment including anti-CD20 antibody, rituximab.