Individualized corrected QT interval is superior to QT interval corrected using the Bazett formula in predicting mutation carriage in families with long QT syndrome

Background Long QT syndrome (LQTS) is characterized by reduced penetrance and variable QT prolongation over time, resulting in an estimate of 25% carriers of a pathogenic mutation with a normal corrected QT (QTc) interval on the resting electrocardiogram (ECG). Objective The purpose of this study wa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Heart rhythm 2017-03, Vol.14 (3), p.376-382
Hauptverfasser: Robyns, Tomas, MD, Willems, Rik, MD, PhD, Vandenberk, Bert, MD, Ector, Joris, MD, PhD, Garweg, Christophe, MD, Kuiperi, Cuno, BSc, Breckpot, Jeroen, MD, PhD, Corveleyn, Anniek, PhD, Janssens, Stefan, MD, PhD, Heidbuchel, Hein, MD, PhD, Nuyens, Dieter, MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Long QT syndrome (LQTS) is characterized by reduced penetrance and variable QT prolongation over time, resulting in an estimate of 25% carriers of a pathogenic mutation with a normal corrected QT (QTc) interval on the resting electrocardiogram (ECG). Objective The purpose of this study was to test the hypothesis that an individualized corrected QT interval derived from 24-hour Holter data more accurately predicts carriage of a pathogenic LQTS mutation than did QT derived from a standard 12-lead ECG and corrected using the Bazett formula (QTc interval). Methods Carriers of a pathogenic LQTS mutation and their genotype-negative family members who had both resting ECG and Holter recordings available were included. Automated and manual measurements of QTc were performed. QTi was derived from 24-hour Holter recordings and defined as the QT value at the intersection of an RR interval of 1000 ms, with the linear regression line fitted through QT-RR data points of each individual patient. Results In total, 69 patients with LQTS (23 long QT type 1, 39 long QT type 2, and 7 long QT type 3) and 55 controls were selected. Demographic characteristics were comparable. A comparison of the receiver operating characteristic curves indicates that the test added diagnostic value compared to manual measurement ( P = .02) or automated measurement ( P = .005). The diagnostic accuracy of manually measured QTc using conventional cutoff criteria was 72%, while it was 92% using a sex-independent QTi cutoff of 445 ms. This was caused by a 39% increase in sensitivity without compromising the specificity. Conclusion QTi derived from Holter recordings is superior to conventional QTc measured from a standard 12-lead ECG in predicting the mutation carrier state in families with LQTS.
ISSN:1547-5271
1556-3871
DOI:10.1016/j.hrthm.2016.11.034