A new validated HPLC method for the determination of quercetin: Application to study pharmacokinetics in rats

A simple, accurate, and reproducible high‐performance liquid chromatography (HPLC) method has been developed and validated for the quantification of quercetin (QR) in rat plasma. The method involves a simple protein precipitation procedure to extract both QR and thymoquinone (TQ), the internal stand...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical chromatography 2017-03, Vol.31 (3), p.np-n/a
Hauptverfasser: Abdelkawy, Khaled S., Balyshev, Mark E., Elbarbry, Fawzy
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A simple, accurate, and reproducible high‐performance liquid chromatography (HPLC) method has been developed and validated for the quantification of quercetin (QR) in rat plasma. The method involves a simple protein precipitation procedure to extract both QR and thymoquinone (TQ), the internal standard. The chromatographic analysis was achieved on a Shimadzu LC 20 A HPLC system equipped with a Supelcosil LC‐18 T C18 column and an isocratic mobile phase consisting of 0.3% trichloroacetic acid in water and acetonitrile HPLC‐grade (50:50, v/v) run at a flow rate of 0.9 mL/min for 13 min. The UV detection wavelength was set at 254 nm. The method exhibited good linearity (R2 > 0.994) over the assayed concentration range (0.10–25 μg/mL) and demonstrated good intra‐day and inter‐day precision and accuracy (relative standard deviations and the deviation from predicted values were
ISSN:0269-3879
1099-0801
DOI:10.1002/bmc.3819