Chlorhexidine-impregnated transparent dressings decrease catheter-related infections in hemodialysis patients: a quality improvement project

Purpose Central venous catheters (CVC) are associated with increased infection rates, morbidity and mortality compared to other hemodialysis vascular access. Chlorhexidine-impregnated transparent (CHG-transparent) dressings allow for continuous antimicrobial exposure and easy visibility of the CVC i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of vascular access 2017-03, Vol.18 (2), p.103-108
Hauptverfasser: Apata, Ibironke W., Hanfelt, John, Bailey, James L., Niyyar, Vandana Dua
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Central venous catheters (CVC) are associated with increased infection rates, morbidity and mortality compared to other hemodialysis vascular access. Chlorhexidine-impregnated transparent (CHG-transparent) dressings allow for continuous antimicrobial exposure and easy visibility of the CVC insertion site. We conducted a quality improvement project to compare catheter-related infection (CRI) rates in two dressing regimens – CHG-transparent dressings and adhesive dry gauze dressing in hemodialysis patients with tunneled CVCs. Methods The study was conducted in two phases. In phase 1, CHG-transparent dressing was introduced to EDC hemodialysis unit, while EDG and EDN hemodialysis units, served as the control sites and maintained adhesive dry gauze dressing. Phase 2 of the study involved replacing the adhesive dry gauze dressing with CHG-transparent dressing at EDG and EDN and maintaining CHG-transparent dressing at EDC. CRI rates at each hemodialysis unit during the 12-month intervention were compared to CRI rates for the 12-month pre-intervention period for each study phase. CRI rates were also compared between all three hemodialysis units. Results In phase 1, CRI rates (per 1000 days) in EDC (intervention site) decreased by 52% (1.69 vs. 0.82, p
ISSN:1129-7298
1724-6032