Numerical Simulation of Airflow Organization Process during Double Highway Tunnel Fire

Taking Majiazhai double highway tunnel as a prototype, the mathematical model of double tunnel fire is established to analyze smoke plume spread and diffusion during air flow organization process of highway tunnel fire. In the conditions of double tunnel fire jet fans closed, tunnel jet fans open, v...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2014-01, Vol.501-504 (Advances in Civil and Structural Engineering III), p.2370-2376
Hauptverfasser: Chen, Mei Zhen, Wang, Hai Yan, Liu, Guo Fa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Taking Majiazhai double highway tunnel as a prototype, the mathematical model of double tunnel fire is established to analyze smoke plume spread and diffusion during air flow organization process of highway tunnel fire. In the conditions of double tunnel fire jet fans closed, tunnel jet fans open, ventilators of tunnel and cross-road open simultaneously, the temperature field, pressure field and concentration field of air flow and smoke relative motion are obtained. Then it puts forward that the key technology for smoke countercurrent control in double tunnel fire is to increase the ventilation resistance in fire source upwind cross-road and reduce the air quantity flowing from tunnel jet fans into cross-road.
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.501-504.2370