Investigation of Uncertainty Sources of Piezoresistive Silicon Based Stress Sensor

The aim of this paper is to get insight into measurement uncertainties for thermomechanical measurements performed using a piezoresistive silicon-based stress sensor in a standard microelectronic package. All used sensors have the same construction, were produced in the same technological processes...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2015-11, Vol.807 (Uncertainty in Mechanical Engineering II), p.45-54
Hauptverfasser: Gromala, Przemyslaw, Mayer, Dirk, Kreyßig, Kerstin, Rzepka, Sven, Palczynska, Alicja, Schindler-Saefkow, Florian, Melz, Tobias
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this paper is to get insight into measurement uncertainties for thermomechanical measurements performed using a piezoresistive silicon-based stress sensor in a standard microelectronic package. All used sensors have the same construction, were produced in the same technological processes at the same time, yet the measurement results show significant distribution. The possible causes for this phenomenon are discussed in this paper. Additionally, Finite Element Method (FEM) model is created and validated, what enables a study of sensitive parameters influencing the measurement uncertainties.
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.807.45