Diagnostic Accuracy of Handheld Dynamometry and 1-Repetition-Maximum Tests for Identifying Meaningful Quadriceps Strength Asymmetries

Study Design Clinical measurement, cross-sectional. Background Quadriceps deficits are common in individuals with knee joint impairments and impact functional and quality-of-life outcomes. Quadriceps strength symmetry influences clinical decisions after knee injury. Isometric electromechanical dynam...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of orthopaedic and sports physical therapy 2017-02, Vol.47 (2), p.97-107
Hauptverfasser: Sinacore, J Anthony, Evans, Andrew M, Lynch, Brittany N, Joreitz, Richard E, Irrgang, James J, Lynch, Andrew D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Study Design Clinical measurement, cross-sectional. Background Quadriceps deficits are common in individuals with knee joint impairments and impact functional and quality-of-life outcomes. Quadriceps strength symmetry influences clinical decisions after knee injury. Isometric electromechanical dynamometry (ISO-ED) is the gold standard for measuring symmetry, but is not available in all clinical settings. Objectives To compare concurrent validity of handheld dynamometry and 1-repetition-maximum leg press, knee extension from 90° to 0°, and knee extension from 90° to 45° to that of ISO-ED in identifying meaningful quadriceps strength deficits. Methods Fifty-six participants with knee joint impairments completed ISO-ED and 4 alternative measures of quadriceps strength symmetry in a single session. Absolute agreement of alternative measures with ISO-ED was calculated with intraclass correlation coefficients (ICCs). Clinical agreement values at thresholds of 80% and 90% symmetry were compared between the alternatives and ISO-ED. Results Knee extension from 90° to 45° (ICC = 0.67) and handheld dynamometry (ICC = 0.70) had the greatest ICCs. Clinical agreement was also best for these measures for 80% symmetry (κ = 0.56 and 0.55, respectively) and 90% symmetry (κ = 0.19 and 0.33, respectively). Conclusion Handheld dynamometry and 1-repetition-maximum testing of knee extension from 90° to 45° are fair alternatives, although symmetry is typically overestimated. Receiver operating characteristic analysis identified alternative measure thresholds that correlated with the 80% and 90% symmetry thresholds on the ISO-ED. Clinicians should use more stringent symmetry values for these alternative tests to increase the probability that individuals have a minimum ISO-ED symmetry of 80% or 90%. J Orthop Sports Phys Ther 2017;47(2):97-107. doi:10.2519/jospt.2017.6651.
ISSN:0190-6011
1938-1344
DOI:10.2519/jospt.2017.6651