Two-dimensional shear-wave elastography: a new method comparable to acoustic radiation force impulse imaging?

OBJECTIVESTwo-dimensional shear-wave elastography (2D-SWE) is an ultrasound-based technique for the noninvasive assessment of tissue stiffness. In contrast to the well-established point-shear-wave elastography (pSWE) method acoustic radiation force impulse imaging, there is little evidence on the pe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of gastroenterology & hepatology 2017-06, Vol.29 (6), p.723-729
Hauptverfasser: Schellhaas, Barbara, Strobel, Deike, Wildner, Dane, Goertz, Ruediger S, Neurath, Markus F, Pfeifer, Lukas
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:OBJECTIVESTwo-dimensional shear-wave elastography (2D-SWE) is an ultrasound-based technique for the noninvasive assessment of tissue stiffness. In contrast to the well-established point-shear-wave elastography (pSWE) method acoustic radiation force impulse imaging, there is little evidence on the performance and usefulness of 2D-SWE in the assessment of liver stiffness. Thus, the aim of our study was to compare 2D-SWE versus pSWE. MATERIALS AND METHODS2D-SWE and pSWE were performed in 20 cirrhotic patients, 20 healthy individuals and an elasticity phantom. Stiffness values, examination time and number of measurements were compared. For 2D-SWE, the influence of size of the region of interest (ROI) was assessed. RESULTSElastography values in healthy individuals were slightly higher for 2D-SWE versus pSWE (1.4 m/s, range1.21–1.68 vs. 1.23 m/s, range1.07–1.39). In cirrhotic patients, there were no significant differences (3.06 m/s, range1.83–5.35 vs. 3 m/s, range1.67–4.37 m/s). Examination times were significantly longer for 2D-SWE in both patient groups (mean values for healthy/cirrhotic patients129.6/157.1 vs. 75/71.6 s). For 2D-SWE, variation of ROI size (5, 10, 20 mm) produced comparable results. After eight measurements, 90% of cirrhotic patients showed less than 5% of deviation from the results after the gold standard of 10 measurements; for healthy individuals, this was observed after six measurements. CONCLUSION2D-SWE seems to be comparable to pSWE (acoustic radiation force impulse-imaging) in cirrhotic patients, with slightly higher values in healthy individuals. 2D-SWE measurements require considerably more time. For 2D-SWE, ROI size seems to be of minor importance; multiple measurements should be obtained as single measurements differ. These preliminary results should be confirmed in larger patient collectives with histology as the reference standard.
ISSN:0954-691X
1473-5687
DOI:10.1097/MEG.0000000000000846