Diagnostic value of core biopsy histology and cytology sampling of mediastinal lymph nodes using 21-gauge EBUS-TBNA needle
Introduction: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the initial modality of choice in sampling mediastinal lymphadenopathy. It is possible to obtain both cytological and histological samples using both 21-gauge and 22-gauge EBUS-TBNA needles. The current stu...
Gespeichert in:
Veröffentlicht in: | Journal of cancer research and therapeutics 2016-07, Vol.12 (3), p.1172-1177 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the initial modality of choice in sampling mediastinal lymphadenopathy. It is possible to obtain both cytological and histological samples using both 21-gauge and 22-gauge EBUS-TBNA needles. The current study was undertaken to compare the diagnostic yield of cytology and histology samples obtained by the same EBUS-TBNA 21-gauge needle.
Patients and Methods: One hundred sixty-six consecutive patients who underwent EBUS-TBNA with a 21-gauge EBUS-TBNA needle over a period of 3 years were included in this retrospective analysis. The diagnostic yields of EBUS-TBNA histology (EBUS-TBNA-H) and EBUS-TBNA cytology (EBUS-TBNA-C) specimens were compared using the McNemar test.
Results: The overall sensitivity and specificity of EBUS-TBNA were 89% and 100%, respectively. The positive predictive value (PPV) and negative predictive value (NPV) of EBUS-TBNA were 100% and 53%, respectively. The overall sensitivity and specificity of EBUS-TBNA-H were 85% and 100%, respectively. The PPV and NPV of EBUS-TBNA-H were 100% and 43%, respectively. The overall sensitivity and specificity of EBUS-TBNA-C were 65% and 100%, respectively. The PPV and NPV of EBUS-TBNA-C were 100% and 14%, respectively. The diagnostic yield of EBUS-TBNA-H over EBUS-TBNA-C was statistically significant (P < 0.0001).
Conclusion: EBUS-TBNA-H with 21-gauge needle significantly improves the diagnostic yield of EBUS-TBNA. EBUS-TBNA-H improves the NPV of EBUS-TBNA. The combination of EBUS-TBNA-H and EBUS-TBNA-C improves the overall diagnostic yield of EBUS-TBNA. |
---|---|
ISSN: | 0973-1482 1998-4138 |
DOI: | 10.4103/0973-1482.197535 |