Detection of the diuretic hydrochlorothiazide in a doping control urine sample as the result of a non-steroidal anti-inflammatory drug (NSAID) tablet contamination
Highlights • Contaminated medications can lead to positive doping controls. • Medications produced under GMP guidelines may lead to positive doping controls. • Diuretics ingested in micrograms are detectable in urine. • Reporting “specified” doping substances below a certain level is inappropriate....
Gespeichert in:
Veröffentlicht in: | Forensic science international 2016-10, Vol.267, p.166-172 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Highlights • Contaminated medications can lead to positive doping controls. • Medications produced under GMP guidelines may lead to positive doping controls. • Diuretics ingested in micrograms are detectable in urine. • Reporting “specified” doping substances below a certain level is inappropriate. |
---|---|