Permeability Measurement of High Performance Concrete at Elevated Temperature Employing a New Test Set-Up
This paper is focused on clarifying behaviour of concrete at elevated temperature with employing new test set-up constructed at Institute of Building Construction and Technology, Vienna University of Technology. This unique test set-up allows measuring gas permeability of different building material...
Gespeichert in:
Veröffentlicht in: | Advanced Materials Research 2015-09, Vol.1124, p.288-293 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper is focused on clarifying behaviour of concrete at elevated temperature with employing new test set-up constructed at Institute of Building Construction and Technology, Vienna University of Technology. This unique test set-up allows measuring gas permeability of different building materials such as concrete or ceramic at both high temperature (up to 400°C) and pressure (up to 6 bars). Present paper illustrates a new set up for permeability measurement during the heating and cooling and different testing procedures and evaluation of their influence on results. |
---|---|
ISSN: | 1022-6680 1662-8985 1662-8985 |