Over-catheter tract suture to prevent bleeding and air embolism after tunnelled catheter removal
Introduction Severe, life-threating, complications might occur on dialysis catheter removal. Methods We present a useful technique that may prevent vascular air embolism and severe bleeding. Results The suture is placed around the catheter and tied over previous tract just after device removal. Conc...
Gespeichert in:
Veröffentlicht in: | The journal of vascular access 2017-03, Vol.18 (2), p.170-172 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction
Severe, life-threating, complications might occur on dialysis catheter removal.
Methods
We present a useful technique that may prevent vascular air embolism and severe bleeding.
Results
The suture is placed around the catheter and tied over previous tract just after device removal.
Conclusions
Applying a compressing suture to the tract left after removal of a tunnelled haemodialysis catheter is a simple manoeuvre that could prevent severe complication. |
---|---|