Evaluation of recombinant human parathyroid hormone by CZE method and its correlation with in vitro bioassay and LC methods

A stability-indicating capillary zone electrophoresis (CZE) method was validated to assess the content/potency of the recombinant human parathyroid hormone (rhPTH 1-34), using ranitidine as internal standard (IS). A fused-silica capillary, (i.d. of 50µm; effective length of 40cm) was used at 25°C; t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2017-01, Vol.162, p.567-573
Hauptverfasser: Maldaner, Fernanda Pavani Stamm, Perobelli, Rafaela Ferreira, Xavier, Bruna, Remuzzi, Gabriel Lunardi, Walter, Maurício Elesbão, Dalmora, Sérgio Luiz
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A stability-indicating capillary zone electrophoresis (CZE) method was validated to assess the content/potency of the recombinant human parathyroid hormone (rhPTH 1-34), using ranitidine as internal standard (IS). A fused-silica capillary, (i.d. of 50µm; effective length of 40cm) was used at 25°C; the applied voltage was 20kV. The background electrolyte solution consisted of 50mmolL−1 sodium dihydrogen phosphate solution at pH 3.0. Injections were performed using a pressure mode at 50 mbar for 45s, with detection by photodiode array (PDA) detector set at 200nm. Separation was obtained with a migration time of 5.3min, and was linear over the concentration range of 0.25–250µgmL−1 (r2 =0.9992). Specificity and stability-indicating capability were established in degradation studies, which also showed that there was no interference of the excipients. The accuracy was 100.28% with bias lower than 0.85%. Analyses of the same batches showed mean differences of the estimated content/potencies of 0.61%, 1.31% higher and 0.86% lower as compared to the validated reversed-phase and size exclusion liquid chromatography methods, and to the UMR-106 cell culture bioassay, respectively, with non-significant differences (p>0.05). Degraded forms were also subjected to the in vitro cytotoxicity test. The results obtained showed the capabilities of each one of the methods, and constitute an alternative strategy to monitor stability, improve the quality control and ensure the batch-to-batch consistency of bulk and finished biotechnology-derived medicine. [Display omitted] •Stability-indicating capillary zone electrophoresis method for rhPTH (1-34).•Correlation between cell-culture bioassay and physicochemical methods for rhPTH (1-34).•Content/potency assessment of rhPTH (1-34) in biotechnology-derived product.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2016.10.053