Time-efficient measurement of multi-phase arterial spin labeling MR signal in white matter
White matter (WM) perfusion has great potential as a physiological biomarker in many neurological diseases. Although it has been demonstrated previously that arterial spin labeling magnetic resonance imaging (ASL‐MRI) enables the detection of the perfusion‐weighted signal in most voxels in WM, studi...
Gespeichert in:
Veröffentlicht in: | NMR in biomedicine 2016-11, Vol.29 (11), p.1519-1525 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | White matter (WM) perfusion has great potential as a physiological biomarker in many neurological diseases. Although it has been demonstrated previously that arterial spin labeling magnetic resonance imaging (ASL‐MRI) enables the detection of the perfusion‐weighted signal in most voxels in WM, studies of cerebral blood flow (CBF) in WM by ASL‐MRI are relatively scarce because of its particular challenges, such as significantly lower perfusion and longer arterial transit times relative to gray matter (GM). Recently, ASL with a spectroscopic readout has been proposed to enhance the sensitivity for the measurement of WM perfusion. However, this approach suffers from long acquisition times, especially when acquiring multi‐phase ASL datasets to improve CBF quantification. Furthermore, the potential increase in the signal‐to‐noise ratio (SNR) by spectroscopic readout compared with echo planar imaging (EPI) readout has not been proven experimentally. In this study, we propose the use of time‐encoded pseudo‐continuous ASL (te‐pCASL) with single‐voxel point‐resolved spectroscopy (PRESS) readout to quantify WM cerebral perfusion in a more time‐efficient manner. Results are compared with te‐pCASL with a conventional EPI readout for both WM and GM perfusion measurements. Perfusion measurements by te‐pCASL PRESS and conventional EPI showed no significant difference for quantitative WM CBF values (Student's t‐test, p = 0.19) or temporal SNR (p = 0.33 and p = 0.81 for GM and WM, respectively), whereas GM CBF values (p = 0.016) were higher using PRESS than EPI readout. WM CBF values were found to be 18.2 ± 7.6 mL/100 g/min (PRESS) and 12.5 ± 5.5 mL/100 g/min (EPI), whereas GM CBF values were found to be 77.1 ± 11.2 mL/100 g/min (PRESS) and 53.6 ± 9.6 mL/100 g/min (EPI). This study demonstrates the feasibility of te‐pCASL PRESS for the quantification of WM perfusion changes in a highly time‐efficient manner, but it does not result in improved temporal SNR, as does traditional te‐pCASL EPI, which remains the preferred option because of its flexibility in use.
Time‐encoded pseudo‐continuous arterial spin labeling (te‐pCASL) with single‐voxel point‐resolved spectroscopy (PRESS) readout is proposed to detect multi‐phase ASL signal in white matter (WM) in a highly time‐efficient manner. te‐pCASL perfusion measurements by PRESS and echo planar imaging (EPI) readout showed no significantly different values for WM cerebral blood flow (CBF) [18.2 ± 7.6 mL/100 g/min (PRESS) versus 1 |
---|---|
ISSN: | 0952-3480 1099-1492 |
DOI: | 10.1002/nbm.3603 |