Esthetic assessment of immediately restored implants combined with GBR and free connective tissue graft

Aim Esthetic assessment of immediately restored implants combined with GBR and free connective tissue (CT) graft Methods A case–control, retrospective study involving 34 patients treated with maxillary anterior single implants, immediately placed and restored. Clinical and esthetic results were anal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical oral implants research 2016-11, Vol.27 (11), p.1414-1422
Hauptverfasser: Kolerman, Roni, Nissan, Joseph, Mijiritsky, Eitan, Hamoudi, Nasreen, Mangano, Carlo, Tal, Haim
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aim Esthetic assessment of immediately restored implants combined with GBR and free connective tissue (CT) graft Methods A case–control, retrospective study involving 34 patients treated with maxillary anterior single implants, immediately placed and restored. Clinical and esthetic results were analyzed using standard clinical examination and a comprehensive index, comprising pink esthetic and white esthetic scores (PES/WES). The height of the implant crown and the corresponding height of the contralateral tooth crown were measured to identify mucosal recessions. The distance from the mucosal margin to the implant shoulder (DIM) was measured on the master model. Results Thirty of 34 implants fulfilled the strict success criteria set for dental implants with regard to osseointegration. Success was defined as implants with bone loss not exceeding 1.5 mm during the first year and loosing not more than 0.2 for each successive year. The other four implants were stable but did not meet the bone loss criteria mentioned above and defined as survived implants. Mean PES/WES was 14.44 ± 2.34 (range: 9–20). Mean PES was 7.12 ± 1.89 (range: 1–10). The highest mean values were achieved for the variable of root convexity/soft tissue color and texture (1.71 ± 0.46) whereas the mesial papilla (1.09 ± 0.62) proved to be the least pleasing. The mean WES was 7.32 ± 1.25 (range: 5–10). The difference between IC and contralateral TC was 0.54 mm. The mean value for the facial DIM was 3.82 ± 0.87 mm. Conclusions An evaluation of soft and hard tissue augmentation in immediately restored immediate implant procedures was employed to obtain stable hard and soft tissues. The combined GBR and CT graft procedure achieved favorable peri‐implant soft tissue condition and esthetic results. However, recession and incomplete papillas were frequently observed.
ISSN:0905-7161
1600-0501
DOI:10.1111/clr.12755