Extraction of Benzoylecgonine from Urine Specimens with Cerex Polycrom™ Clin II Solid-Phase Extraction Columns and the Speedisk™ Pressure Processor

Benzoylecgonine (BZE) extraction from urine was explored using Cerex Polycrom Clin II solid-phase extraction (SPE) columns and the Speedisk 48 Pressure Processor as an alternative to the Prep™1 automated sample processor and XTRX™ Type RP/W columns. Linearity for urine standards extracted using the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of analytical toxicology 2001-10, Vol.25 (7), p.616-620
Hauptverfasser: Kuhnle, Judith A., Churley, Melissa, Kawasaki, Shiralen Y., Lyons, Timothy P., Bruins, Mark R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 620
container_issue 7
container_start_page 616
container_title Journal of analytical toxicology
container_volume 25
creator Kuhnle, Judith A.
Churley, Melissa
Kawasaki, Shiralen Y.
Lyons, Timothy P.
Bruins, Mark R.
description Benzoylecgonine (BZE) extraction from urine was explored using Cerex Polycrom Clin II solid-phase extraction (SPE) columns and the Speedisk 48 Pressure Processor as an alternative to the Prep™1 automated sample processor and XTRX™ Type RP/W columns. Linearity for urine standards extracted using the Cerex-Speedisk method ranged from 20 to 3000 ng/mL. The mean recovery at the 100-ng/mL cutoff for three lots of columns was 92%. The mean of the within-run means for three batches, which had coefficients of variations of 1.8% or less, was 101.3 ng/mL at the lO0-ng/mL cutoff level. Forty-six specimens known to contain BZE were analyzed by both the Prep1-Type RP/W and Cerex-Speedisk methods. The correlation for specimen BZE concentrations between the two methods gave an r2 of 0.9999 and a slope of 1.03. The Cerex-Speedisk system is an inexpensive alternative to the Prep1-Type RP/W system. It is less costly, requires little maintenance, has a small footprint, is hood compatible, and can process four times the number of specimens in a given time.
doi_str_mv 10.1093/jat/25.7.616
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_18297441</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/jat/25.7.616</oup_id><sourcerecordid>18297441</sourcerecordid><originalsourceid>FETCH-LOGICAL-c426t-c64fbdfbfb79de3a7aeb172043d379711397df1cde77a421da71296f9e587363</originalsourceid><addsrcrecordid>eNqFkcGO0zAQhi0EYsvCjTPyCS6ka8eOXR8hWthqK1HUIhAXy4kn1LtJXOxEtJx5B-48Gk-CSyvgxmn-wzefNPMj9JiSKSWKXdyY4SIvpnIqqLiDJlTxIss5YXfRhFAuMi4FOUMPYrwhhIqZYPfRGaWFUoKSCfp-uRuCqQfne-wb_BL6r37fQv3J964H3ATf4XfhEFdbqF0HfcRf3LDBJQTY4aVv93Vifn77gcvW9Xg-xyvfOpstNyYC_sde-nbs0rbpLR42v31gXbw9rC4DxDgGSMHXKfrwEN1rTBvh0Wmeo_Wry3V5lS3evJ6XLxZZzXMxZLXgTWWbqqmkssCMNFBRmRPOLJNKUsqUtA2tLUhpeE6tkTRXolFQzCQT7Bw9PWq3wX8eIQ66c7GGtjU9-DFqOsuV5Jwm8PkRTNfGGKDR2-A6E_aaEn3oQacedF5oqVMPCX9y8o5VB_YvfHp8Ap4dAT9u_6fKjqSLA-z-sCbcaiGZLPTVh496sV6t3q6vr_V79gsQiqTn</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>18297441</pqid></control><display><type>article</type><title>Extraction of Benzoylecgonine from Urine Specimens with Cerex Polycrom™ Clin II Solid-Phase Extraction Columns and the Speedisk™ Pressure Processor</title><source>Oxford University Press Journals All Titles (1996-Current)</source><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Kuhnle, Judith A. ; Churley, Melissa ; Kawasaki, Shiralen Y. ; Lyons, Timothy P. ; Bruins, Mark R.</creator><creatorcontrib>Kuhnle, Judith A. ; Churley, Melissa ; Kawasaki, Shiralen Y. ; Lyons, Timothy P. ; Bruins, Mark R.</creatorcontrib><description>Benzoylecgonine (BZE) extraction from urine was explored using Cerex Polycrom Clin II solid-phase extraction (SPE) columns and the Speedisk 48 Pressure Processor as an alternative to the Prep™1 automated sample processor and XTRX™ Type RP/W columns. Linearity for urine standards extracted using the Cerex-Speedisk method ranged from 20 to 3000 ng/mL. The mean recovery at the 100-ng/mL cutoff for three lots of columns was 92%. The mean of the within-run means for three batches, which had coefficients of variations of 1.8% or less, was 101.3 ng/mL at the lO0-ng/mL cutoff level. Forty-six specimens known to contain BZE were analyzed by both the Prep1-Type RP/W and Cerex-Speedisk methods. The correlation for specimen BZE concentrations between the two methods gave an r2 of 0.9999 and a slope of 1.03. The Cerex-Speedisk system is an inexpensive alternative to the Prep1-Type RP/W system. It is less costly, requires little maintenance, has a small footprint, is hood compatible, and can process four times the number of specimens in a given time.</description><identifier>ISSN: 0146-4760</identifier><identifier>EISSN: 1945-2403</identifier><identifier>DOI: 10.1093/jat/25.7.616</identifier><identifier>PMID: 11599610</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Automation ; benzoylecgonine ; Chromatography, Ion Exchange - methods ; Cocaine - analogs &amp; derivatives ; Cocaine - urine ; Cocaine-Related Disorders - diagnosis ; Humans ; Particle Size ; Sensitivity and Specificity ; Substance Abuse Detection - methods</subject><ispartof>Journal of analytical toxicology, 2001-10, Vol.25 (7), p.616-620</ispartof><rights>2001</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c426t-c64fbdfbfb79de3a7aeb172043d379711397df1cde77a421da71296f9e587363</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1578,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11599610$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kuhnle, Judith A.</creatorcontrib><creatorcontrib>Churley, Melissa</creatorcontrib><creatorcontrib>Kawasaki, Shiralen Y.</creatorcontrib><creatorcontrib>Lyons, Timothy P.</creatorcontrib><creatorcontrib>Bruins, Mark R.</creatorcontrib><title>Extraction of Benzoylecgonine from Urine Specimens with Cerex Polycrom™ Clin II Solid-Phase Extraction Columns and the Speedisk™ Pressure Processor</title><title>Journal of analytical toxicology</title><addtitle>Journal of Analytical Toxicology</addtitle><addtitle>Journal of Analytical Toxicology</addtitle><description>Benzoylecgonine (BZE) extraction from urine was explored using Cerex Polycrom Clin II solid-phase extraction (SPE) columns and the Speedisk 48 Pressure Processor as an alternative to the Prep™1 automated sample processor and XTRX™ Type RP/W columns. Linearity for urine standards extracted using the Cerex-Speedisk method ranged from 20 to 3000 ng/mL. The mean recovery at the 100-ng/mL cutoff for three lots of columns was 92%. The mean of the within-run means for three batches, which had coefficients of variations of 1.8% or less, was 101.3 ng/mL at the lO0-ng/mL cutoff level. Forty-six specimens known to contain BZE were analyzed by both the Prep1-Type RP/W and Cerex-Speedisk methods. The correlation for specimen BZE concentrations between the two methods gave an r2 of 0.9999 and a slope of 1.03. The Cerex-Speedisk system is an inexpensive alternative to the Prep1-Type RP/W system. It is less costly, requires little maintenance, has a small footprint, is hood compatible, and can process four times the number of specimens in a given time.</description><subject>Automation</subject><subject>benzoylecgonine</subject><subject>Chromatography, Ion Exchange - methods</subject><subject>Cocaine - analogs &amp; derivatives</subject><subject>Cocaine - urine</subject><subject>Cocaine-Related Disorders - diagnosis</subject><subject>Humans</subject><subject>Particle Size</subject><subject>Sensitivity and Specificity</subject><subject>Substance Abuse Detection - methods</subject><issn>0146-4760</issn><issn>1945-2403</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkcGO0zAQhi0EYsvCjTPyCS6ka8eOXR8hWthqK1HUIhAXy4kn1LtJXOxEtJx5B-48Gk-CSyvgxmn-wzefNPMj9JiSKSWKXdyY4SIvpnIqqLiDJlTxIss5YXfRhFAuMi4FOUMPYrwhhIqZYPfRGaWFUoKSCfp-uRuCqQfne-wb_BL6r37fQv3J964H3ATf4XfhEFdbqF0HfcRf3LDBJQTY4aVv93Vifn77gcvW9Xg-xyvfOpstNyYC_sde-nbs0rbpLR42v31gXbw9rC4DxDgGSMHXKfrwEN1rTBvh0Wmeo_Wry3V5lS3evJ6XLxZZzXMxZLXgTWWbqqmkssCMNFBRmRPOLJNKUsqUtA2tLUhpeE6tkTRXolFQzCQT7Bw9PWq3wX8eIQ66c7GGtjU9-DFqOsuV5Jwm8PkRTNfGGKDR2-A6E_aaEn3oQacedF5oqVMPCX9y8o5VB_YvfHp8Ap4dAT9u_6fKjqSLA-z-sCbcaiGZLPTVh496sV6t3q6vr_V79gsQiqTn</recordid><startdate>20011001</startdate><enddate>20011001</enddate><creator>Kuhnle, Judith A.</creator><creator>Churley, Melissa</creator><creator>Kawasaki, Shiralen Y.</creator><creator>Lyons, Timothy P.</creator><creator>Bruins, Mark R.</creator><general>Oxford University Press</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U7</scope><scope>C1K</scope></search><sort><creationdate>20011001</creationdate><title>Extraction of Benzoylecgonine from Urine Specimens with Cerex Polycrom™ Clin II Solid-Phase Extraction Columns and the Speedisk™ Pressure Processor</title><author>Kuhnle, Judith A. ; Churley, Melissa ; Kawasaki, Shiralen Y. ; Lyons, Timothy P. ; Bruins, Mark R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c426t-c64fbdfbfb79de3a7aeb172043d379711397df1cde77a421da71296f9e587363</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Automation</topic><topic>benzoylecgonine</topic><topic>Chromatography, Ion Exchange - methods</topic><topic>Cocaine - analogs &amp; derivatives</topic><topic>Cocaine - urine</topic><topic>Cocaine-Related Disorders - diagnosis</topic><topic>Humans</topic><topic>Particle Size</topic><topic>Sensitivity and Specificity</topic><topic>Substance Abuse Detection - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kuhnle, Judith A.</creatorcontrib><creatorcontrib>Churley, Melissa</creatorcontrib><creatorcontrib>Kawasaki, Shiralen Y.</creatorcontrib><creatorcontrib>Lyons, Timothy P.</creatorcontrib><creatorcontrib>Bruins, Mark R.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Toxicology Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Journal of analytical toxicology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kuhnle, Judith A.</au><au>Churley, Melissa</au><au>Kawasaki, Shiralen Y.</au><au>Lyons, Timothy P.</au><au>Bruins, Mark R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Extraction of Benzoylecgonine from Urine Specimens with Cerex Polycrom™ Clin II Solid-Phase Extraction Columns and the Speedisk™ Pressure Processor</atitle><jtitle>Journal of analytical toxicology</jtitle><stitle>Journal of Analytical Toxicology</stitle><addtitle>Journal of Analytical Toxicology</addtitle><date>2001-10-01</date><risdate>2001</risdate><volume>25</volume><issue>7</issue><spage>616</spage><epage>620</epage><pages>616-620</pages><issn>0146-4760</issn><eissn>1945-2403</eissn><abstract>Benzoylecgonine (BZE) extraction from urine was explored using Cerex Polycrom Clin II solid-phase extraction (SPE) columns and the Speedisk 48 Pressure Processor as an alternative to the Prep™1 automated sample processor and XTRX™ Type RP/W columns. Linearity for urine standards extracted using the Cerex-Speedisk method ranged from 20 to 3000 ng/mL. The mean recovery at the 100-ng/mL cutoff for three lots of columns was 92%. The mean of the within-run means for three batches, which had coefficients of variations of 1.8% or less, was 101.3 ng/mL at the lO0-ng/mL cutoff level. Forty-six specimens known to contain BZE were analyzed by both the Prep1-Type RP/W and Cerex-Speedisk methods. The correlation for specimen BZE concentrations between the two methods gave an r2 of 0.9999 and a slope of 1.03. The Cerex-Speedisk system is an inexpensive alternative to the Prep1-Type RP/W system. It is less costly, requires little maintenance, has a small footprint, is hood compatible, and can process four times the number of specimens in a given time.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>11599610</pmid><doi>10.1093/jat/25.7.616</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0146-4760
ispartof Journal of analytical toxicology, 2001-10, Vol.25 (7), p.616-620
issn 0146-4760
1945-2403
language eng
recordid cdi_proquest_miscellaneous_18297441
source Oxford University Press Journals All Titles (1996-Current); MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Automation
benzoylecgonine
Chromatography, Ion Exchange - methods
Cocaine - analogs & derivatives
Cocaine - urine
Cocaine-Related Disorders - diagnosis
Humans
Particle Size
Sensitivity and Specificity
Substance Abuse Detection - methods
title Extraction of Benzoylecgonine from Urine Specimens with Cerex Polycrom™ Clin II Solid-Phase Extraction Columns and the Speedisk™ Pressure Processor
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T20%3A17%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Extraction%20of%20Benzoylecgonine%20from%20Urine%20Specimens%20with%20Cerex%20Polycrom%E2%84%A2%20Clin%20II%20Solid-Phase%20Extraction%20Columns%20and%20the%20Speedisk%E2%84%A2%20Pressure%20Processor&rft.jtitle=Journal%20of%20analytical%20toxicology&rft.au=Kuhnle,%20Judith%20A.&rft.date=2001-10-01&rft.volume=25&rft.issue=7&rft.spage=616&rft.epage=620&rft.pages=616-620&rft.issn=0146-4760&rft.eissn=1945-2403&rft_id=info:doi/10.1093/jat/25.7.616&rft_dat=%3Cproquest_cross%3E18297441%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=18297441&rft_id=info:pmid/11599610&rft_oup_id=10.1093/jat/25.7.616&rfr_iscdi=true