Endovascular Repair of an Aortic Arch Aneurysm with Triple Chimney Stent Grafts: A Case Report
The treatment of an aortic arch aneurysm in high-risk individuals poses a significant challenge. We present a surgical patient with a patent left internal mammary artery (LIMA) graft and a large aortic arch aneurysm who underwent aortic stent-graft implantation and complete endovascular branching to...
Gespeichert in:
Veröffentlicht in: | Annals of vascular surgery 2016-10, Vol.36, p.297.e1-297.e5 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The treatment of an aortic arch aneurysm in high-risk individuals poses a significant challenge. We present a surgical patient with a patent left internal mammary artery (LIMA) graft and a large aortic arch aneurysm who underwent aortic stent-graft implantation and complete endovascular branching to preserve the LIMA inflow, with successful exclusion of the aneurysm. A moderate flow, proximal type I endoleak was observed after deployment that disappeared at 2-year follow-up. |
---|---|
ISSN: | 0890-5096 1615-5947 |
DOI: | 10.1016/j.avsg.2016.03.033 |