Validity of Guatemalan Mother’s Self-Reported Breast-Feeding Practices of 3-Month-Old Infants

Introduction: Breast-feeding practices (BFPs) can be assessed by interviewing the mother about current feeding practices and with a 24-hour recall. It is crucial to establish the accuracy of these methods, which are commonly used by public health decision makers to design health policies aimed at in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Food and nutrition bulletin 2016-12, Vol.37 (4), p.494-503
Hauptverfasser: Mazariegos, Monica, Slater, Christine, Ramirez-Zea, Manuel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction: Breast-feeding practices (BFPs) can be assessed by interviewing the mother about current feeding practices and with a 24-hour recall. It is crucial to establish the accuracy of these methods, which are commonly used by public health decision makers to design health policies aimed at increasing exclusive breast-feeding rates. Objective: We aimed to validate 2 self-report BFP instruments using the dose-to-mother deuterium oxide turnover technique (DMDOT) as the reference method. Methods: Breast-feeding practices were assessed by interviewing the mother about current feeding practices and with a 24-hour recall in 36 Guatemalan mother–infant pairs. The validity of these instruments was assessed using DMDOT as the reference method. Results: Both self-report instruments overestimated exclusively breast-fed (EBF) infants. Infants classified as EBF were 50% by the reported current feeding practice, 61% by the 24-hour recall, and only 36% using DMDOT. Sensitivity to detect EBF infants from the mother’s self-report was 92% (95% CI: 62%-99%) while from the 24-hour recall was 100% (95% CI: 72%-100%, P < .01). However, specificity for both instruments was low, at 74% (95% CI: 51%-89%) for reported current feeding practice and at 61% (95% CI: 39%-79%) for the 24-hour recall (P < .01). Conclusion: Both reported current feeding practice and the 24-hour recall instruments overestimated exclusive breast-feeding. Nevertheless, the use of reported current feeding practice provided more accurate data to assess BFPs in a public health setting. Furthermore, population-based surveys should consider the overestimation of exclusive breast-feeding caused when using these BFP instruments.
ISSN:0379-5721
1564-8265
DOI:10.1177/0379572116654644