A prospective, multicenter, observational study on quality of life after laparoscopic inguinal hernia repair with ProGrip laparoscopic, self-fixating mesh according to the European Registry for Abdominal Wall Hernias Quality of Life Instrument

Background There is an increasing interest in patient-reported outcome measurement to evaluate hernia operations. Several hernia-specific quality of life (QoL) scales have been proposed, but none are constructed for preoperative assessment. Methods The European Registry for Abdominal Wall Hernias (E...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Surgery 2016-11, Vol.160 (5), p.1344-1357
Hauptverfasser: Muysoms, Filip E., PhD, Vanlander, Aude, MD, Ceulemans, Robrecht, MD, Kyle-Leinhase, Iris, PhD, Michiels, Maarten, MD, Jacobs, Ivo, MD, Pletinckx, Pieter, MD, Berrevoet, Frederik, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background There is an increasing interest in patient-reported outcome measurement to evaluate hernia operations. Several hernia-specific quality of life (QoL) scales have been proposed, but none are constructed for preoperative assessment. Methods The European Registry for Abdominal Wall Hernias (EuraHS) proposed the short, 9-question EuraHS-QoL instrument for assessment pre- and postoperatively. The EuraHS-QoL was evaluated in a prospective, multicenter validation study alongside the Visual Analogue Scale, Verbal Rating Scale, and Carolina Comfort Scale ( https://clinicaltrials.gov ; NCT01936584 ). Results We included 101 patients undergoing unilateral laparoscopic inguinal hernia repair with ProGrip laparoscopic, self-fixating mesh. Clinical follow-up at 12 months was 87% complete. The EuraHS-QoL score shows good internal consistency (Cronbach's α ≥ .90), good test-retest reliability (Spearman correlation coefficient r ≥ 0.72), and high correlation for pain with the Visual Analogue Scale, the Verbal Rating Scale, the Carolina Comfort Scale pain scale (r between 0.64 and 0.86), and for restriction of activity with the Carolina Comfort Scale movement scale (r between 0.65 and 0.79). Our results show significant improvement in quality of life at 3 weeks compared with preoperative and further significant improvement at 12 months ( P  75%) or with a 95%) in the majority of the patients. Conclusion The EuraHS-QoL instrument is a short and valid patient-reported outcome measurement following groin hernia repair. Laparoscopic inguinal hernia repair with ProGrip laparoscopic, self-fixating mesh results in a favorable outcome and significant improvement of quality of life compared with the preoperative assessment.
ISSN:0039-6060
1532-7361
DOI:10.1016/j.surg.2016.04.026