Comparison of two methods for measurement of equine insulin

Diagnosis of equine hyperinsulinemia requires an accurate method for quantification of equine insulin concentrations. The objectives of the current study were to compare 2 commercially available techniques for measurement of equine insulin, the radioimmunoassay (RIA) and chemiluminescent immunoassay...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of veterinary diagnostic investigation 2014-07, Vol.26 (4), p.527-530
Hauptverfasser: Banse, Heidi E., McCann, Joseph, Yang, Fan, Wagg, Catherine, McFarlane, Dianne
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 530
container_issue 4
container_start_page 527
container_title Journal of veterinary diagnostic investigation
container_volume 26
creator Banse, Heidi E.
McCann, Joseph
Yang, Fan
Wagg, Catherine
McFarlane, Dianne
description Diagnosis of equine hyperinsulinemia requires an accurate method for quantification of equine insulin concentrations. The objectives of the current study were to compare 2 commercially available techniques for measurement of equine insulin, the radioimmunoassay (RIA) and chemiluminescent immunoassay (CIA). Recovery was poor for both assays, but worse for the CIA. Serial dilution of a high endogenous insulin sample yielded better linearity for the RIA (r2 = 0.99, P < 0.001) than the CIA (r2 = 0.92, P = 0.009). Bland–Altman analysis indicated that the CIA was, on average, 91 pmol/l higher than the RIA, with wide limits of agreement (95% limits of agreement: –508 to 691 pmol/l). These findings suggest that results between the assays should not be considered interchangeable.
doi_str_mv 10.1177/1040638714536560
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1826594384</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1040638714536560</sage_id><sourcerecordid>1826594384</sourcerecordid><originalsourceid>FETCH-LOGICAL-c379t-ff9ccbe3e97a53db0c5c6f2090e3f701f61ac3bfbf9fefa2c70b8cb6be5939b93</originalsourceid><addsrcrecordid>eNp1kM1LAzEUxIMotlbvnmSPXlaTzSbZ4ElK_YCCFz2HJH3RLbubNtkg_vemtHoQPL2B-c3AG4QuCb4hRIhbgmvMaSNIzShnHB-hKZE1LWtJ-XHW2S53_gSdxbjGmFVMkFM0qWpZNUw2U3Q39_1Ghzb6ofCuGD990cP44VexcD5krWMK0MMw7mzYpnaAoh1i6trhHJ043UW4ONwZentYvM6fyuXL4_P8fllaKuRYOietNUBBCs3oymDLLHcVlhioE5g4TrSlxhknHThdWYFNYw03wCSVRtIZut73boLfJoij6ttooev0AD5FRZqKs_x2U2cU71EbfIwBnNqEttfhSxGsdpOpv5PlyNWhPZkeVr-Bn40yUO6BqN9BrX0KQ_72_8JvEZh0TQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1826594384</pqid></control><display><type>article</type><title>Comparison of two methods for measurement of equine insulin</title><source>Access via SAGE</source><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Banse, Heidi E. ; McCann, Joseph ; Yang, Fan ; Wagg, Catherine ; McFarlane, Dianne</creator><creatorcontrib>Banse, Heidi E. ; McCann, Joseph ; Yang, Fan ; Wagg, Catherine ; McFarlane, Dianne</creatorcontrib><description>Diagnosis of equine hyperinsulinemia requires an accurate method for quantification of equine insulin concentrations. The objectives of the current study were to compare 2 commercially available techniques for measurement of equine insulin, the radioimmunoassay (RIA) and chemiluminescent immunoassay (CIA). Recovery was poor for both assays, but worse for the CIA. Serial dilution of a high endogenous insulin sample yielded better linearity for the RIA (r2 = 0.99, P &lt; 0.001) than the CIA (r2 = 0.92, P = 0.009). Bland–Altman analysis indicated that the CIA was, on average, 91 pmol/l higher than the RIA, with wide limits of agreement (95% limits of agreement: –508 to 691 pmol/l). These findings suggest that results between the assays should not be considered interchangeable.</description><identifier>ISSN: 1040-6387</identifier><identifier>EISSN: 1943-4936</identifier><identifier>DOI: 10.1177/1040638714536560</identifier><identifier>PMID: 24928598</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Animals ; Horses - metabolism ; Insulin - metabolism ; Luminescent Measurements - methods ; Luminescent Measurements - veterinary ; Radioimmunoassay - methods ; Radioimmunoassay - veterinary ; Reproducibility of Results ; Sensitivity and Specificity</subject><ispartof>Journal of veterinary diagnostic investigation, 2014-07, Vol.26 (4), p.527-530</ispartof><rights>2014 The Author(s)</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c379t-ff9ccbe3e97a53db0c5c6f2090e3f701f61ac3bfbf9fefa2c70b8cb6be5939b93</citedby><cites>FETCH-LOGICAL-c379t-ff9ccbe3e97a53db0c5c6f2090e3f701f61ac3bfbf9fefa2c70b8cb6be5939b93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1040638714536560$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1040638714536560$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24928598$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Banse, Heidi E.</creatorcontrib><creatorcontrib>McCann, Joseph</creatorcontrib><creatorcontrib>Yang, Fan</creatorcontrib><creatorcontrib>Wagg, Catherine</creatorcontrib><creatorcontrib>McFarlane, Dianne</creatorcontrib><title>Comparison of two methods for measurement of equine insulin</title><title>Journal of veterinary diagnostic investigation</title><addtitle>J Vet Diagn Invest</addtitle><description>Diagnosis of equine hyperinsulinemia requires an accurate method for quantification of equine insulin concentrations. The objectives of the current study were to compare 2 commercially available techniques for measurement of equine insulin, the radioimmunoassay (RIA) and chemiluminescent immunoassay (CIA). Recovery was poor for both assays, but worse for the CIA. Serial dilution of a high endogenous insulin sample yielded better linearity for the RIA (r2 = 0.99, P &lt; 0.001) than the CIA (r2 = 0.92, P = 0.009). Bland–Altman analysis indicated that the CIA was, on average, 91 pmol/l higher than the RIA, with wide limits of agreement (95% limits of agreement: –508 to 691 pmol/l). These findings suggest that results between the assays should not be considered interchangeable.</description><subject>Animals</subject><subject>Horses - metabolism</subject><subject>Insulin - metabolism</subject><subject>Luminescent Measurements - methods</subject><subject>Luminescent Measurements - veterinary</subject><subject>Radioimmunoassay - methods</subject><subject>Radioimmunoassay - veterinary</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><issn>1040-6387</issn><issn>1943-4936</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kM1LAzEUxIMotlbvnmSPXlaTzSbZ4ElK_YCCFz2HJH3RLbubNtkg_vemtHoQPL2B-c3AG4QuCb4hRIhbgmvMaSNIzShnHB-hKZE1LWtJ-XHW2S53_gSdxbjGmFVMkFM0qWpZNUw2U3Q39_1Ghzb6ofCuGD990cP44VexcD5krWMK0MMw7mzYpnaAoh1i6trhHJ043UW4ONwZentYvM6fyuXL4_P8fllaKuRYOietNUBBCs3oymDLLHcVlhioE5g4TrSlxhknHThdWYFNYw03wCSVRtIZut73boLfJoij6ttooev0AD5FRZqKs_x2U2cU71EbfIwBnNqEttfhSxGsdpOpv5PlyNWhPZkeVr-Bn40yUO6BqN9BrX0KQ_72_8JvEZh0TQ</recordid><startdate>20140701</startdate><enddate>20140701</enddate><creator>Banse, Heidi E.</creator><creator>McCann, Joseph</creator><creator>Yang, Fan</creator><creator>Wagg, Catherine</creator><creator>McFarlane, Dianne</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20140701</creationdate><title>Comparison of two methods for measurement of equine insulin</title><author>Banse, Heidi E. ; McCann, Joseph ; Yang, Fan ; Wagg, Catherine ; McFarlane, Dianne</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c379t-ff9ccbe3e97a53db0c5c6f2090e3f701f61ac3bfbf9fefa2c70b8cb6be5939b93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Animals</topic><topic>Horses - metabolism</topic><topic>Insulin - metabolism</topic><topic>Luminescent Measurements - methods</topic><topic>Luminescent Measurements - veterinary</topic><topic>Radioimmunoassay - methods</topic><topic>Radioimmunoassay - veterinary</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Banse, Heidi E.</creatorcontrib><creatorcontrib>McCann, Joseph</creatorcontrib><creatorcontrib>Yang, Fan</creatorcontrib><creatorcontrib>Wagg, Catherine</creatorcontrib><creatorcontrib>McFarlane, Dianne</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of veterinary diagnostic investigation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Banse, Heidi E.</au><au>McCann, Joseph</au><au>Yang, Fan</au><au>Wagg, Catherine</au><au>McFarlane, Dianne</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of two methods for measurement of equine insulin</atitle><jtitle>Journal of veterinary diagnostic investigation</jtitle><addtitle>J Vet Diagn Invest</addtitle><date>2014-07-01</date><risdate>2014</risdate><volume>26</volume><issue>4</issue><spage>527</spage><epage>530</epage><pages>527-530</pages><issn>1040-6387</issn><eissn>1943-4936</eissn><abstract>Diagnosis of equine hyperinsulinemia requires an accurate method for quantification of equine insulin concentrations. The objectives of the current study were to compare 2 commercially available techniques for measurement of equine insulin, the radioimmunoassay (RIA) and chemiluminescent immunoassay (CIA). Recovery was poor for both assays, but worse for the CIA. Serial dilution of a high endogenous insulin sample yielded better linearity for the RIA (r2 = 0.99, P &lt; 0.001) than the CIA (r2 = 0.92, P = 0.009). Bland–Altman analysis indicated that the CIA was, on average, 91 pmol/l higher than the RIA, with wide limits of agreement (95% limits of agreement: –508 to 691 pmol/l). These findings suggest that results between the assays should not be considered interchangeable.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>24928598</pmid><doi>10.1177/1040638714536560</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1040-6387
ispartof Journal of veterinary diagnostic investigation, 2014-07, Vol.26 (4), p.527-530
issn 1040-6387
1943-4936
language eng
recordid cdi_proquest_miscellaneous_1826594384
source Access via SAGE; MEDLINE; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
subjects Animals
Horses - metabolism
Insulin - metabolism
Luminescent Measurements - methods
Luminescent Measurements - veterinary
Radioimmunoassay - methods
Radioimmunoassay - veterinary
Reproducibility of Results
Sensitivity and Specificity
title Comparison of two methods for measurement of equine insulin
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T11%3A54%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20two%20methods%20for%20measurement%20of%20equine%20insulin&rft.jtitle=Journal%20of%20veterinary%20diagnostic%20investigation&rft.au=Banse,%20Heidi%20E.&rft.date=2014-07-01&rft.volume=26&rft.issue=4&rft.spage=527&rft.epage=530&rft.pages=527-530&rft.issn=1040-6387&rft.eissn=1943-4936&rft_id=info:doi/10.1177/1040638714536560&rft_dat=%3Cproquest_cross%3E1826594384%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1826594384&rft_id=info:pmid/24928598&rft_sage_id=10.1177_1040638714536560&rfr_iscdi=true