Non-occlusive mesenteric ischemia (NOMI): utility of measuring the diameters of the superior mesenteric artery and superior mesenteric vein at multidetector CT
Objective To investigate the diagnostic capability of multidetector computed tomography for detecting non-occlusive mesenteric ischemia (NOMI). Methods We studied 11 NOMI patients and 44 controls. Radiologists evaluated the CT images for the presence of bowel ischemia and measured the diameters of t...
Gespeichert in:
Veröffentlicht in: | Japanese journal of radiology 2013-11, Vol.31 (11), p.737-743 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective
To investigate the diagnostic capability of multidetector computed tomography for detecting non-occlusive mesenteric ischemia (NOMI).
Methods
We studied 11 NOMI patients and 44 controls. Radiologists evaluated the CT images for the presence of bowel ischemia and measured the diameters of the superior mesenteric artery and the superior mesenteric vein (
D
SMA
and
D
SMV
). We also performed linear discriminant analysis (LDA) using
D
SMA
and
D
SMV
.
Results
All NOMI patients presented with more than 2 CT findings of bowel ischemia.
D
SMA
and
D
SMV
were significantly smaller in NOMI patients than in the controls (
p
|
---|---|
ISSN: | 1867-1071 1867-108X |
DOI: | 10.1007/s11604-013-0245-1 |