Derivation of zero-sequence circulating current and the compensation of delta-connected static var generators for unbalanced load
Cascaded static var generators (SVG) with delta-configuration is discussed for a compensation of reactive, negative-sequence and harmonic currents. According to phasor analysis of negative-sequence current compensation, the role of zero-sequence circulating current for power balance is analysed. Acc...
Gespeichert in:
Veröffentlicht in: | IET power electronics 2016-03, Vol.9 (3), p.576-588 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Cascaded static var generators (SVG) with delta-configuration is discussed for a compensation of reactive, negative-sequence and harmonic currents. According to phasor analysis of negative-sequence current compensation, the role of zero-sequence circulating current for power balance is analysed. According to power analysis, the analytical expressions of zero-sequence circulating current and 2nd frequency ripples of dc-link voltages are derived. On the basis of this, the phase-current reference detection and the simplified control method of SVG for negative-sequence current compensation are proposed, which is concise and can achieve power balance of three-phase clusters by superimposing a zero-sequence circulating current without additional controllers. Finally, the simulation and experimental results have effectively verified the proposed method. |
---|---|
ISSN: | 1755-4535 1755-4543 1755-4543 |
DOI: | 10.1049/iet-pel.2014.0682 |