A sensitive and selective on-line amperometric sulfite biosensor using sulfite oxidase immobilized on a magnetite-gold-folate nanocomposite modified carbon-paste electrode

We describe a novel amperometric sulfite biosensor, comprising a carbon-paste electrode (Fe3O4@Au-Cys-FA/CPE) modified with immobilized sulfite oxidase (SOx) on a gold-coated magnetite nanoparticle core, encased within a conjugated folic acid (FA) cysteine (Cys) shell. The biosensor electrode was fa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2016-08, Vol.156-157, p.154-162
Hauptverfasser: Sroysee, Wongduan, Ponlakhet, Kitayanan, Chairam, Sanoe, Jarujamrus, Purim, Amatatongchai, Maliwan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We describe a novel amperometric sulfite biosensor, comprising a carbon-paste electrode (Fe3O4@Au-Cys-FA/CPE) modified with immobilized sulfite oxidase (SOx) on a gold-coated magnetite nanoparticle core, encased within a conjugated folic acid (FA) cysteine (Cys) shell. The biosensor electrode was fabricated using a polydimethylsiloxane (PDMS) and mineral oil mixture as binder, which also enhances the physical stability and sensitivity of the electrode. The developed biosensor displays good electrocatalytic activity toward oxidation of H2O2, which occurs by an enzymatic reaction between SOx and sulfite. The Fe3O4@Au-Cys-FA electrode exhibits good electrocatalytic activity, and has good retention of chemisorbed SOx on the electrode because of its large surface area. Sulfite was quantified using amperometric measurements from the Fe3O4@Au-Cys-FA/CPE biosensor, and using an in-house assembled flow cell at +0.35V (vs. Ag/AgCl), with a phosphate buffer carrier (0.10M, pH 7.0) at a flow rate of 0.8mLmin−1. The system detects sulfite over the range 0.1–200mgL−1 (r2=0.998), with a detection limit of 10µgL−1 (3σ of blank). The system exhibits acceptable precision (%R.S.D.=3.1%), rapid sample throughput (109samplesh−1), and good stability (2w). The developed biosensor shows satisfactory tolerance to potential interferences, such as sugars, anions, ascorbic acid, and ethanol. We applied the developed method to the determination of sulfite content in wines and pickled food extracts, and our results are in good agreement with those obtained by the standard iodometric method. [Display omitted] •Carbon-paste electrode modified with immobilized SOx on a Fe3O4@Au-Cys-Fa.•Catalytic detection of Fe3O4@Au-Cys-FA to H2O2.•High sample throughput of A Fe3O4@Au-Cys-FA/CPE used in a FI system.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2016.04.066