Multifunctional nanoanalytics and long-range scanning probe microscope using a nanopositioning and nanomeasuring machine

An interferometer-based metrological scanning probe microscope (SPM) is successfully integrated into our nanopositioning and nanomeasuring machine (NPM machine) for high-precision measurements with nanometre uncertainty over a range of 25 mm × 25 mm × 5 mm. Both devices were developed at the Institu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement science & technology 2014-04, Vol.25 (4), p.44006-7
Hauptverfasser: Vorbringer-Dorozhovets, N, Goj, B, Machleidt, T, Franke, K-H, Hoffmann, M, Manske, E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 7
container_issue 4
container_start_page 44006
container_title Measurement science & technology
container_volume 25
creator Vorbringer-Dorozhovets, N
Goj, B
Machleidt, T
Franke, K-H
Hoffmann, M
Manske, E
description An interferometer-based metrological scanning probe microscope (SPM) is successfully integrated into our nanopositioning and nanomeasuring machine (NPM machine) for high-precision measurements with nanometre uncertainty over a range of 25 mm × 25 mm × 5 mm. Both devices were developed at the Institute of Process Measurement and Sensor Technology of Ilmenau University of Technology, Germany. Outstanding results were achieved for different measurement tasks. With the NPM machine, truly long-range and long-term measurements are possible. Due to the tip wear, an automatic SPM cantilever replacement is preferable. Such a tip replacement is also required for the integration of multifunctional nanoanalytics. For example, for Kelvin probe force microscopy (KPFM), the measurement of topography and surface potential with different SPM tips is necessary. For this purpose, an electromagnetic tip changer was designed. The tip changer comprises three SPM probes. In order to retrieve the previous tip positions, additional fiducial marks were developed. The repeatability of relocation is less than 10 nm. The automatic tip changer and fiducial marks are integrated into a sample holder. The tip changer in combination with fiducial marks allows scanning distances three times longer (with the same type of SPM probes) and multifunctional nanoanalytics (with different SPM probes with special properties). Sample KPFM measurements are demonstrated. The developed tip changer, including special fiducial marks, improves the performance and functionality of the NPM machine crucially.
doi_str_mv 10.1088/0957-0233/25/4/044006
format Article
fullrecord <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_proquest_miscellaneous_1825529344</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1825529344</sourcerecordid><originalsourceid>FETCH-LOGICAL-c328t-1405e072dc07df560fc6265a0fce0dca5b4d57c8554a1238f86c4731c712db3c3</originalsourceid><addsrcrecordid>eNqFkEtLxDAUhYMoOI7-BKFLN7U3rz6WMvgCxY2uQyZNxwxtUpMGnH9vMxW3ru7lcM7h3g-hawy3GOq6gIZXORBKC8ILVgBjAOUJWmFa4rzkgE_R6s9zji5C2ANABU2zQt-vsZ9MF62ajLOyz6y0Ts7LYTIqZNK2We_sLvfS7nQWlLTW2F02erfV2WCUd0G5UWcxJFke46MLJrUdlbkgaYOWIfqkDFJ9Gqsv0Vkn-6CvfucafTzcv2-e8pe3x-fN3UuuKKmnHDPgGirSKqjajpfQqZKUXM5TQ6sk37KWV6rmnElMaN3VpWIVxarCpN1SRdfoZumdT_6KOkxiMEHpvpdWuxgErgnnpKGMzVa-WNNXwetOjN4M0h8EBpFIi0RRJIqCcMHEQnrO4SVn3Cj2LvoZX_gn8wMXFoK6</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1825529344</pqid></control><display><type>article</type><title>Multifunctional nanoanalytics and long-range scanning probe microscope using a nanopositioning and nanomeasuring machine</title><source>Institute of Physics Journals</source><creator>Vorbringer-Dorozhovets, N ; Goj, B ; Machleidt, T ; Franke, K-H ; Hoffmann, M ; Manske, E</creator><creatorcontrib>Vorbringer-Dorozhovets, N ; Goj, B ; Machleidt, T ; Franke, K-H ; Hoffmann, M ; Manske, E</creatorcontrib><description>An interferometer-based metrological scanning probe microscope (SPM) is successfully integrated into our nanopositioning and nanomeasuring machine (NPM machine) for high-precision measurements with nanometre uncertainty over a range of 25 mm × 25 mm × 5 mm. Both devices were developed at the Institute of Process Measurement and Sensor Technology of Ilmenau University of Technology, Germany. Outstanding results were achieved for different measurement tasks. With the NPM machine, truly long-range and long-term measurements are possible. Due to the tip wear, an automatic SPM cantilever replacement is preferable. Such a tip replacement is also required for the integration of multifunctional nanoanalytics. For example, for Kelvin probe force microscopy (KPFM), the measurement of topography and surface potential with different SPM tips is necessary. For this purpose, an electromagnetic tip changer was designed. The tip changer comprises three SPM probes. In order to retrieve the previous tip positions, additional fiducial marks were developed. The repeatability of relocation is less than 10 nm. The automatic tip changer and fiducial marks are integrated into a sample holder. The tip changer in combination with fiducial marks allows scanning distances three times longer (with the same type of SPM probes) and multifunctional nanoanalytics (with different SPM probes with special properties). Sample KPFM measurements are demonstrated. The developed tip changer, including special fiducial marks, improves the performance and functionality of the NPM machine crucially.</description><identifier>ISSN: 0957-0233</identifier><identifier>EISSN: 1361-6501</identifier><identifier>DOI: 10.1088/0957-0233/25/4/044006</identifier><identifier>CODEN: MSTCEP</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>AFM ; Automation ; Devices ; electromagnetic changer for SPM probes ; fiducial marks ; metrological scanning probe microscope ; Microscopy ; nanopositioning and nanomeasuring machine ; Nanostructure ; Scanning probe microscopes ; Tips ; Topography ; Wear</subject><ispartof>Measurement science &amp; technology, 2014-04, Vol.25 (4), p.44006-7</ispartof><rights>2014 IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c328t-1405e072dc07df560fc6265a0fce0dca5b4d57c8554a1238f86c4731c712db3c3</citedby><cites>FETCH-LOGICAL-c328t-1405e072dc07df560fc6265a0fce0dca5b4d57c8554a1238f86c4731c712db3c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0957-0233/25/4/044006/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27924,27925,53846,53893</link.rule.ids></links><search><creatorcontrib>Vorbringer-Dorozhovets, N</creatorcontrib><creatorcontrib>Goj, B</creatorcontrib><creatorcontrib>Machleidt, T</creatorcontrib><creatorcontrib>Franke, K-H</creatorcontrib><creatorcontrib>Hoffmann, M</creatorcontrib><creatorcontrib>Manske, E</creatorcontrib><title>Multifunctional nanoanalytics and long-range scanning probe microscope using a nanopositioning and nanomeasuring machine</title><title>Measurement science &amp; technology</title><addtitle>MST</addtitle><addtitle>Meas. Sci. Technol</addtitle><description>An interferometer-based metrological scanning probe microscope (SPM) is successfully integrated into our nanopositioning and nanomeasuring machine (NPM machine) for high-precision measurements with nanometre uncertainty over a range of 25 mm × 25 mm × 5 mm. Both devices were developed at the Institute of Process Measurement and Sensor Technology of Ilmenau University of Technology, Germany. Outstanding results were achieved for different measurement tasks. With the NPM machine, truly long-range and long-term measurements are possible. Due to the tip wear, an automatic SPM cantilever replacement is preferable. Such a tip replacement is also required for the integration of multifunctional nanoanalytics. For example, for Kelvin probe force microscopy (KPFM), the measurement of topography and surface potential with different SPM tips is necessary. For this purpose, an electromagnetic tip changer was designed. The tip changer comprises three SPM probes. In order to retrieve the previous tip positions, additional fiducial marks were developed. The repeatability of relocation is less than 10 nm. The automatic tip changer and fiducial marks are integrated into a sample holder. The tip changer in combination with fiducial marks allows scanning distances three times longer (with the same type of SPM probes) and multifunctional nanoanalytics (with different SPM probes with special properties). Sample KPFM measurements are demonstrated. The developed tip changer, including special fiducial marks, improves the performance and functionality of the NPM machine crucially.</description><subject>AFM</subject><subject>Automation</subject><subject>Devices</subject><subject>electromagnetic changer for SPM probes</subject><subject>fiducial marks</subject><subject>metrological scanning probe microscope</subject><subject>Microscopy</subject><subject>nanopositioning and nanomeasuring machine</subject><subject>Nanostructure</subject><subject>Scanning probe microscopes</subject><subject>Tips</subject><subject>Topography</subject><subject>Wear</subject><issn>0957-0233</issn><issn>1361-6501</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLxDAUhYMoOI7-BKFLN7U3rz6WMvgCxY2uQyZNxwxtUpMGnH9vMxW3ru7lcM7h3g-hawy3GOq6gIZXORBKC8ILVgBjAOUJWmFa4rzkgE_R6s9zji5C2ANABU2zQt-vsZ9MF62ajLOyz6y0Ts7LYTIqZNK2We_sLvfS7nQWlLTW2F02erfV2WCUd0G5UWcxJFke46MLJrUdlbkgaYOWIfqkDFJ9Gqsv0Vkn-6CvfucafTzcv2-e8pe3x-fN3UuuKKmnHDPgGirSKqjajpfQqZKUXM5TQ6sk37KWV6rmnElMaN3VpWIVxarCpN1SRdfoZumdT_6KOkxiMEHpvpdWuxgErgnnpKGMzVa-WNNXwetOjN4M0h8EBpFIi0RRJIqCcMHEQnrO4SVn3Cj2LvoZX_gn8wMXFoK6</recordid><startdate>20140401</startdate><enddate>20140401</enddate><creator>Vorbringer-Dorozhovets, N</creator><creator>Goj, B</creator><creator>Machleidt, T</creator><creator>Franke, K-H</creator><creator>Hoffmann, M</creator><creator>Manske, E</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20140401</creationdate><title>Multifunctional nanoanalytics and long-range scanning probe microscope using a nanopositioning and nanomeasuring machine</title><author>Vorbringer-Dorozhovets, N ; Goj, B ; Machleidt, T ; Franke, K-H ; Hoffmann, M ; Manske, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c328t-1405e072dc07df560fc6265a0fce0dca5b4d57c8554a1238f86c4731c712db3c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>AFM</topic><topic>Automation</topic><topic>Devices</topic><topic>electromagnetic changer for SPM probes</topic><topic>fiducial marks</topic><topic>metrological scanning probe microscope</topic><topic>Microscopy</topic><topic>nanopositioning and nanomeasuring machine</topic><topic>Nanostructure</topic><topic>Scanning probe microscopes</topic><topic>Tips</topic><topic>Topography</topic><topic>Wear</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vorbringer-Dorozhovets, N</creatorcontrib><creatorcontrib>Goj, B</creatorcontrib><creatorcontrib>Machleidt, T</creatorcontrib><creatorcontrib>Franke, K-H</creatorcontrib><creatorcontrib>Hoffmann, M</creatorcontrib><creatorcontrib>Manske, E</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Measurement science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vorbringer-Dorozhovets, N</au><au>Goj, B</au><au>Machleidt, T</au><au>Franke, K-H</au><au>Hoffmann, M</au><au>Manske, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multifunctional nanoanalytics and long-range scanning probe microscope using a nanopositioning and nanomeasuring machine</atitle><jtitle>Measurement science &amp; technology</jtitle><stitle>MST</stitle><addtitle>Meas. Sci. Technol</addtitle><date>2014-04-01</date><risdate>2014</risdate><volume>25</volume><issue>4</issue><spage>44006</spage><epage>7</epage><pages>44006-7</pages><issn>0957-0233</issn><eissn>1361-6501</eissn><coden>MSTCEP</coden><abstract>An interferometer-based metrological scanning probe microscope (SPM) is successfully integrated into our nanopositioning and nanomeasuring machine (NPM machine) for high-precision measurements with nanometre uncertainty over a range of 25 mm × 25 mm × 5 mm. Both devices were developed at the Institute of Process Measurement and Sensor Technology of Ilmenau University of Technology, Germany. Outstanding results were achieved for different measurement tasks. With the NPM machine, truly long-range and long-term measurements are possible. Due to the tip wear, an automatic SPM cantilever replacement is preferable. Such a tip replacement is also required for the integration of multifunctional nanoanalytics. For example, for Kelvin probe force microscopy (KPFM), the measurement of topography and surface potential with different SPM tips is necessary. For this purpose, an electromagnetic tip changer was designed. The tip changer comprises three SPM probes. In order to retrieve the previous tip positions, additional fiducial marks were developed. The repeatability of relocation is less than 10 nm. The automatic tip changer and fiducial marks are integrated into a sample holder. The tip changer in combination with fiducial marks allows scanning distances three times longer (with the same type of SPM probes) and multifunctional nanoanalytics (with different SPM probes with special properties). Sample KPFM measurements are demonstrated. The developed tip changer, including special fiducial marks, improves the performance and functionality of the NPM machine crucially.</abstract><pub>IOP Publishing</pub><doi>10.1088/0957-0233/25/4/044006</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0957-0233
ispartof Measurement science & technology, 2014-04, Vol.25 (4), p.44006-7
issn 0957-0233
1361-6501
language eng
recordid cdi_proquest_miscellaneous_1825529344
source Institute of Physics Journals
subjects AFM
Automation
Devices
electromagnetic changer for SPM probes
fiducial marks
metrological scanning probe microscope
Microscopy
nanopositioning and nanomeasuring machine
Nanostructure
Scanning probe microscopes
Tips
Topography
Wear
title Multifunctional nanoanalytics and long-range scanning probe microscope using a nanopositioning and nanomeasuring machine
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T12%3A53%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multifunctional%20nanoanalytics%20and%20long-range%20scanning%20probe%20microscope%20using%20a%20nanopositioning%20and%20nanomeasuring%20machine&rft.jtitle=Measurement%20science%20&%20technology&rft.au=Vorbringer-Dorozhovets,%20N&rft.date=2014-04-01&rft.volume=25&rft.issue=4&rft.spage=44006&rft.epage=7&rft.pages=44006-7&rft.issn=0957-0233&rft.eissn=1361-6501&rft.coden=MSTCEP&rft_id=info:doi/10.1088/0957-0233/25/4/044006&rft_dat=%3Cproquest_iop_j%3E1825529344%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1825529344&rft_id=info:pmid/&rfr_iscdi=true