Clinical feasibility of Gd-EOB-DTPA-enhanced MR imaging for assessing liver function: Validation with ICG tests and parenchymal cell volume

Abstract Objective Using Gd-EOB-DTPA-enhanced MRI to assess liver function and validate with indocyanine green (ICG) tests and parenchymal cell volume (PCV). Methods Nineteen patients scheduled for operation were enrolled. Functional liver volume (FLV) was computed from 20 minutes post-contrast imag...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical imaging 2016-07, Vol.40 (4), p.797-800
Hauptverfasser: Chang, Chin-Chen, Huang, Hsu-Cheng, Liu, Kao-Lang, Wu, Yao-Ming, Lee, Jason J.S, Jiang, Shu-Fen, Su, Mao-Yuan M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Objective Using Gd-EOB-DTPA-enhanced MRI to assess liver function and validate with indocyanine green (ICG) tests and parenchymal cell volume (PCV). Methods Nineteen patients scheduled for operation were enrolled. Functional liver volume (FLV) was computed from 20 minutes post-contrast images. ICG retention was measured in serum 15 minutes after injection. The histological PCV was determined from resected liver specimen. Results FLV showed significantly correlated with ICG retention (ICG-R15: r = -0.47, p = 0.042) and PCV (r = 0.814, P < 0.001). Conclusions Gd-EOB-DTPA-enhanced MRI is clinically feasible for quantifying liver function.
ISSN:0899-7071
1873-4499
DOI:10.1016/j.clinimag.2016.03.003