Polydiacetylene Liposomal Aequorin Bioluminescent Device for Detection of Hydrophobic Compounds

In this study, a polydiacetylene liposomal aequorin bioluminescent device (PLABD) that functioned through control of the membrane transport of Ca2+ ions was developed for detecting hydrophobic compounds. In the PLABD, aequorin was encapsulated in an internal water phase and a calcium ionophore (CI)...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical chemistry (Washington) 2016-06, Vol.88 (11), p.5704-5709
Hauptverfasser: Yamamoto, Ryoko, Takegami, Shigehiko, Konishi, Atsuko, Horikawa, Hikari, Yonezawa, Sayumi, Kitade, Tatsuya
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, a polydiacetylene liposomal aequorin bioluminescent device (PLABD) that functioned through control of the membrane transport of Ca2+ ions was developed for detecting hydrophobic compounds. In the PLABD, aequorin was encapsulated in an internal water phase and a calcium ionophore (CI) was contained in a hydrophobic region. Membrane transport of Ca2+ ions across the CI was suppressed by polymerization between diacetylene molecules. On addition of an analyte, the membrane transport of Ca2+ ions across the CI increased, and Ca2+ ions from the external water phase could diffuse into the internal water phase via the CI, which resulted in bioluminescence of the aequorin. Lidocaine, procaine, and procainamide were used as model compounds to test the validity of the detection mechanism of the PLABD. When each analyte was added to a suspension of the PLABD, bioluminescence from the aequorin in the PLABD was observed, and the level of this bioluminescence increased with increasing analyte concentration. There was a linear relationship between the logarithm of the analyte concentration and the bioluminescence for all analytes as follows: R = 0.89 from 10 nmol L–1 to 10 mmol L–1 for lidocaine, R = 0.66 from 10 nmol L–1 to 100 μmol L–1 for procaine, and R = 0.74 from 100 nmol L–1 to 100 μmol L–1 for procainamide. Compared to the traditional colorimetric method using polydiacetylene liposome, the PLABD was superior for both the sensitivity and dynamic range. Thus, PLABD is a valid, simple, and sensitive signal generator for detection of hydrophobic compounds that interact with PLABD membranes.
ISSN:0003-2700
1520-6882
DOI:10.1021/acs.analchem.5b04500