Displacement timer pins: An experimental method for measuring the dynamic deformation of explosively loaded plates

The measurement of dynamic deformation of an explosively loaded plate is an extremely onerous task. Existing techniques such as digital image correlation are expensive and the equipment may be damaged by explosively driven debris/ejecta, particularly if it is necessary to locate such equipment close...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of impact engineering 2015-12, Vol.86, p.124-130
Hauptverfasser: Fay, S.D., Rigby, S.E., Tyas, A., Clarke, S.D., Reay, J.J., Warren, J.A., Brown, R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The measurement of dynamic deformation of an explosively loaded plate is an extremely onerous task. Existing techniques such as digital image correlation are expensive and the equipment may be damaged by explosively driven debris/ejecta, particularly if it is necessary to locate such equipment close to loaded elements which are likely to fail. A new, inexpensive and robust measurement technique for use in full-scale blast testing is presented, which involves the placement of displacement timer pins (DTPs) at pre-defined distances from the rear surface of the centre of a plate. A strain gauge on the perimeter of each pin records the time at which the plate comes into contact with the end of each DTP and hence has deformed to that value of displacement, giving a direct measure of the time-varying deformation at a discrete point on the plate. An experimental proof-of-concept was conducted and the results are compared with numerical displacements determined using LS-DYNA. The numerical and experimental results were in very good agreement, which suggests that the proposed experimental method offers a valuable means for determining the full-scale response of structures subjected to blast loads in aggressive environments. Further improvements to the experimental procedure are outlined, along with applications where the DTPs are particularly suited. •Novel experimental technique presented for measuring plate deformation termed DTPs.•DTPs record impact with rear of plate, displacement-time calculated from DTP array.•Experimental proof-of-concept conducted. Excellent agreement with numerical model.•DTPs suited for aggressive loading scenarios and are accurate, low-cost and robust.
ISSN:0734-743X
1879-3509
DOI:10.1016/j.ijimpeng.2015.08.002