Calibration of visual model for space manipulator with a hybrid LM–GA algorithm
A hybrid LM–GA algorithm is proposed to calibrate the camera system of space manipulator to improve its locational accuracy. This algorithm can dynamically fuse the Levenberg–Marqurdt (LM) algorithm and Genetic Algorithm (GA) together to minimize the error of nonlinear camera model. LM algorithm is...
Gespeichert in:
Veröffentlicht in: | Mechanical systems and signal processing 2016-01, Vol.66-67, p.399-409 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A hybrid LM–GA algorithm is proposed to calibrate the camera system of space manipulator to improve its locational accuracy. This algorithm can dynamically fuse the Levenberg–Marqurdt (LM) algorithm and Genetic Algorithm (GA) together to minimize the error of nonlinear camera model. LM algorithm is called to optimize the initial camera parameters that are generated by genetic process previously. Iteration should be stopped if the optimized camera parameters meet the accuracy requirements. Otherwise, new populations are generated again by GA and optimized afresh by LM algorithm until the optimal solutions meet the accuracy requirements. A novel measuring machine of space manipulator is designed to on-orbit dynamic simulation and precision test. The camera system of space manipulator, calibrated by hybrid LM–GA algorithm, is used for locational precision test in this measuring instrument. The experimental results show that the mean composite errors are 0.074mm for hybrid LM–GA camera calibration model, 1.098mm for LM camera calibration model, and 1.202mm for GA camera calibration model. Furthermore, the composite standard deviations are 0.103mm for the hybrid LM–GA camera calibration model, 1.227mm for LM camera calibration model, and 1.351mm for GA camera calibration model. The accuracy of hybrid LM–GA camera calibration model is more than 10 times higher than that of other two methods. All in all, the hybrid LM–GA camera calibration model is superior to both the LM camera calibration model and GA camera calibration model.
•Build a hybrid LM–GA algorithm to optimize nonlinear equations with multiple peak values.•Build a hybrid LM–GA camera calibration model of space manipulator.•This model can improve locational accuracy of visual system.•Design a novel measuring machine of space manipulator.•This machine is used for dynamic orbital simulation and precision test. |
---|---|
ISSN: | 0888-3270 1096-1216 |
DOI: | 10.1016/j.ymssp.2015.05.033 |