Remote Monitoring of Implantable Cardioverter-Defibrillators: A Systematic Review and Meta-Analysis of Clinical Outcomes

Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized controlled trial (RCT) and several large device database studies have demonstrated a powerful survival advantage for ICD patients undergoing R...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American College of Cardiology 2015-06, Vol.65 (24), p.2591-2600
Hauptverfasser: Parthiban, Nirmalatiban, Esterman, Adrian, Mahajan, Rajiv, Twomey, Darragh J, Pathak, Rajeev K, Lau, Dennis H, Roberts-Thomson, Kurt C, Young, Glenn D, Sanders, Prashanthan, Ganesan, Anand N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized controlled trial (RCT) and several large device database studies have demonstrated a powerful survival advantage for ICD patients undergoing RM compared with those receiving conventional in-office (IO) follow-up. This study sought to conduct a systematic published data review and meta-analysis of RCTs comparing RM with IO follow-up. Electronic databases and reference lists were searched for RCTs reporting clinical outcomes in ICD patients who did or did not undergo RM. Data were extracted from 9 RCTs, including 6,469 patients, 3,496 of whom were randomized to RM and 2,973 to IO follow-up. In the RCT setting, RM demonstrated clinical outcomes comparable with office follow-up in terms of all-cause mortality (odds ratio [OR]: 0.83; p = 0.285), cardiovascular mortality (OR: 0.66; p = 0.103), and hospitalization (OR: 0.83; p = 0.196). However, a reduction in all-cause mortality was noted in the 3 trials using home monitoring (OR: 0.65; p = 0.021) with daily verification of transmission. Although the odds of receiving any ICD shock were similar in RM and IO patients (OR: 1.05; p = 0.86), the odds of inappropriate shock were reduced in RM patients (OR: 0.55; p = 0.002). Meta-analysis of RCTs demonstrates that RM and IO follow-up showed comparable overall outcomes related to patient safety and survival, with a potential survival benefit in RCTs using daily transmission verification. RM benefits include more rapid clinical event detection and a reduction in inappropriate shocks.
ISSN:0735-1097
1558-3597
DOI:10.1016/j.jacc.2015.04.029