Experimental study of a replaceable steel coupling beam with an end-plate connection
In order to enhance the post-damage repair capability of the hybrid coupled shear wall systems, a different type of replaceable steel coupling beam with end-plate connection was investigated. Different from conventional configurations, the coupling beams were not embedded into the walls to minimize...
Gespeichert in:
Veröffentlicht in: | Journal of constructional steel research 2016-07, Vol.122, p.138-150 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In order to enhance the post-damage repair capability of the hybrid coupled shear wall systems, a different type of replaceable steel coupling beam with end-plate connection was investigated. Different from conventional configurations, the coupling beams were not embedded into the walls to minimize the post-event repair/replacement difficulties and expenses. To assess the seismic behavior and post-damage replaceability of the coupling beam, a two-stage experimental program was performed to test the full-scale specimens, each utilizing coupling beams with different strength and stiffness. The results of the first specimen indicated a ductile failure with a concentration of inelastic deformation at steel web and thus exhibited desirable deformation and energy absorption capacities with minimum damages to the shear wall. Again, on the minimum repaired wall-pier, the second specimen via the proposed connection, with improved characteristics such as strength and stiffness, was installed and tested. The results demonstrated excellent stiffness, strength, and ductility characteristics of subassemblages under cyclic loading, with considerable energy dissipation concentrated in the coupling beam web. Although the second specimen failed from the threaded area of the tensile bolts, due to increased coupling beam strength, the specimens were able to sustain large nonlinear displacements without significant damage in the connection to the wall pier regions; representing that this connection configuration would require little repair, if any, after a severe earthquake.
•Steel coupling beams with end-plate connections on a wall-pier were studied.•The experiment was conducted in two stages with same wall-pier.•The strength, stiffness, and energy dissipation of the specimens were investigated.•The proposed configuration behaved suitable enough with least post-damage repairing. |
---|---|
ISSN: | 0143-974X 1873-5983 |
DOI: | 10.1016/j.jcsr.2016.03.018 |