The SSTARS (STeroids and Stents Against Re-Stenosis) Trial: Different stent alloys and the use of peri-procedural oral corticosteroids to prevent in-segment restenosis after percutaneous coronary intervention

Abstract Background Stent design and technological modifications to allow for anti-proliferative drug elution influence restenosis rates following percutaneous coronary intervention (PCI). We aimed to investigate whether peri-procedural administration of corticosteroids or the use of thinner strut c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of cardiology 2016-08, Vol.216, p.1-8
Hauptverfasser: Adam, Z, Turley, A, Mason, J.M, Kasim, A.S, Newby, D, Mills, N, Padfield, G, Thompson, L, Morley, R, Hall, J.A, Wright, R.A, Muir, D.F, Sutton, A.G.C, Swanson, N, Carter, J, Bilous, R, Jones, S, de Belder, M.A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Stent design and technological modifications to allow for anti-proliferative drug elution influence restenosis rates following percutaneous coronary intervention (PCI). We aimed to investigate whether peri-procedural administration of corticosteroids or the use of thinner strut cobalt alloy stents would reduce rates of binary angiographic restenosis (BAR) after PCI. Methods This was a two centre, mixed single and double blinded, randomised controlled trial using a factorial design. We compared (a) the use of prednisolone to placebo, starting at least six hours pre-PCI and continued for 28 days post-PCI, and (b) cobalt chromium (CoCr) to stainless steel (SS) alloy stents, in patients admitted for PCI. The primary end-point was BAR at six months. Results 315 patients (359 lesions) were randomly assigned to either placebo (n = 145) or prednisolone (n = 170) and SS (n = 160) or CoCr (n = 160). The majority (58%) presented with an ACS, 11% had diabetes and 287 (91%) completed angiographic follow up. BAR occurred in 26 cases in the placebo group (19.7%) versus 31 cases in the prednisolone group (20.0%) respectively, p = 1.00. For the comparison between SS and CoCr stents, BAR occurred in 32 patients (21.6%) versus 25 patients (18.0%) respectively, p = 0.46. Conclusion Our study showed that treating patients with a moderately high dose of prednisolone for 28 days following PCI with BMS did not reduce the incidence of BAR. In addition, we showed no significant reduction in 6 month restenosis rates with stents composed of CoCr alloy compared to SS ( http://www.isrctn.com/ISRCTN05886349 ).
ISSN:0167-5273