PO-0710Dosing Errors And Clinical Impact In Preterm Infants Due To Flow Rate Variability In Mult-infusion Therapy

Background and aimsAlmost all preterm infants on the NICU receive continuous intra-venous infusion therapy. Commonly, multiple pharmaceuticals are administered through one catheter (multi-infusion). Due to the mutual influence of infusion pumps, dosing errors can occur that may lead to adverse event...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of disease in childhood 2014-10, Vol.99 (Suppl 2), p.A486-A486
Hauptverfasser: Snijder, R A, Timmerman, AMDE, Riphagen, B, Lucas, P, Lemmers, PMA, van Bel, F, Egberts, ACG
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background and aimsAlmost all preterm infants on the NICU receive continuous intra-venous infusion therapy. Commonly, multiple pharmaceuticals are administered through one catheter (multi-infusion). Due to the mutual influence of infusion pumps, dosing errors can occur that may lead to adverse events. We designed an in vitro experiment to measure flow rate variability and dosing errors. Subsequently, possible clinical impact was investigated.MethodsWe conducted an n = 3 experiment with 3 syringe pumps and disposables as used in our NICU. A clinically relevant medication schedule was simulated using laser dyes as substitutes for pharmaceuticals. Real-time, inline, absorption spectrometry was used to measure dye concentrations and, subsequently, analyse flow rate variability. After changing the flow rate we registered temporary dosing errors in the parallel pumps, in addition, we registered start-up delays. A one-compartment pharmacological model was used to investigate the clinical impact of these errors.ResultsThe significant temporary dosing errors were between 48.1% plus or minus 12.9% and -32.5% plus or minus 22.5% over- and under-dose respectively. Start-up delays were up to 0.71 plus or minus 0.11 h. Our pharmacological model indicates that these dosing errors could lead to haemodynamic instability for commonly used inotropes.ConclusionsPotential clinical impact includes hypertension, hypotension and intraventricular haemorrhages. We conclude that applying multi-infusion with currently used NICU infusion setups results in dosing errors with potential clinical impact. It is advised not to combine high-alert medication on a mutual lumen or line. In addition, it is advised to raise awareness about these phenomena.This study was co-funded by the EMRP.
ISSN:0003-9888
DOI:10.1136/archdischild-2014-307384.1346