PS-129Continuous Subcutaneous Glucose Monitoring (cgm) During Paediatric Critical Care

Background and aimsThe last decade gave clear evidence that hyper/hypoglycemia and glucose variability are associated with increased mortality in critically ill patients. Continuous glucose monitor (CGM) is a new device in paediatric critical care units (PICU) with clear advantages in glucose monito...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of disease in childhood 2014-10, Vol.99 (Suppl 2), p.A157-A157
Hauptverfasser: Marics, G, Lodi, C, Koncz, L, Eitler, K, Szenasi, B, Zakarias, D, Mikos, B, Toth-Heyn, P
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background and aimsThe last decade gave clear evidence that hyper/hypoglycemia and glucose variability are associated with increased mortality in critically ill patients. Continuous glucose monitor (CGM) is a new device in paediatric critical care units (PICU) with clear advantages in glucose monitoring. The aim of our study was to survey the incidence of glucose regulation disorders in our PICU and specify the association between the PRISM III score and the glycemic variability [mean amplitude of glycemic action (MAGE)].MethodsWe evaluated 22 children: mean age: 1.3 years, mean length of PICU stay: 18 days; 20/22 patients were on invasive mechanical ventilation; 6/22 needed vasoactive agent therapy. CGM duration: 1-12 days. Interstitial glucose level was monitored by Guardian registered REAL Time CGM (Medtronic registered ). Reference glucose values were obtained from blood gas analyzer or point-of-care glucose analyzer. We used Spearman correlation to evaluate the association between PRISM III and the MAGE.ResultsHypo- and hyperglycemia (CGM glucose < 55 mg/dl / CGM glucose > 180 mg/dl) were detected in 4.6% and 2.5% of measurements, respectively. The mean MAGE (meaningful excursion >45 mg/dl) and PRISM III were 78 mg/dl and 19. We found a significant correlation between PRISM III and MAGE (r = 0,55; p < 0.05). Pearson's correlation coefficient (0.82) and Clarke Error Grid analysis (96% clinical accuracy) proved a good reliability of the CGM.ConclusionsGlucose homeostasis disorders are frequent in the PICU; hypoglycemia being more commonly detected. Increased PRISM III score contributes significantly to the elevation of glucose variability.
ISSN:0003-9888
DOI:10.1136/archdischild-2014-307384.424