Micro-CT imaging: Developing criteria for examining fetal skeletons in regulatory developmental toxicology studies – A workshop report

During the past two decades the use and refinements of imaging modalities have markedly increased making it possible to image embryos and fetuses used in pivotal nonclinical studies submitted to regulatory agencies. Implementing these technologies into the Good Laboratory Practice environment requir...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Regulatory toxicology and pharmacology 2016-06, Vol.77, p.100-108
Hauptverfasser: Solomon, Howard M., Makris, Susan L., Alsaid, Hasan, Bermudez, Oscar, Beyer, Bruce K., Chen, Antong, Chen, Connie L., Chen, Zhou, Chmielewski, Gary, DeLise, Anthony M., de Schaepdrijver, Luc, Dogdas, Belma, French, Julian, Harrouk, Wafa, Helfgott, Jonathan, Henkelman, R. Mark, Hesterman, Jacob, Hew, Kok-Wah, Hoberman, Alan, Lo, Cecilia W., McDougal, Andrew, Minck, Daniel R., Scott, Lelia, Stewart, Jane, Sutherland, Vicki, Tatiparthi, Arun K., Winkelmann, Christopher T., Wise, L. David, Wood, Sandra L., Ying, Xiaoyou
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:During the past two decades the use and refinements of imaging modalities have markedly increased making it possible to image embryos and fetuses used in pivotal nonclinical studies submitted to regulatory agencies. Implementing these technologies into the Good Laboratory Practice environment requires rigorous testing, validation, and documentation to ensure the reproducibility of data. A workshop on current practices and regulatory requirements was held with the goal of defining minimal criteria for the proper implementation of these technologies and subsequent submission to regulatory agencies. Micro-computed tomography (micro-CT) is especially well suited for high-throughput evaluations, and is gaining popularity to evaluate fetal skeletons to assess the potential developmental toxicity of test agents. This workshop was convened to help scientists in the developmental toxicology field understand and apply micro-CT technology to nonclinical toxicology studies and facilitate the regulatory acceptance of imaging data. Presentations and workshop discussions covered: (1) principles of micro-CT fetal imaging; (2) concordance of findings with conventional skeletal evaluations; and (3) regulatory requirements for validating the system. Establishing these requirements for micro-CT examination can provide a path forward for laboratories considering implementing this technology and provide regulatory agencies with a basis to consider the acceptability of data generated via this technology. •Defining minimal criteria for implementing micro-CT for fetal skeleton evaluation.•Concordance between new and existing fetal skeleton examination methods.•GLP validation and regulatory requirements.
ISSN:0273-2300
1096-0295
DOI:10.1016/j.yrtph.2016.02.018