Dental color matching: A comparison between visual and instrumental methods

The aim of this study was to compare the agreement rate (%) and color difference (ΔE*ab) of three dental color-measuring devices, with the visual shade identification. The tooth color were determined by two operators, which were advised to select a VITA classic shade tab in each other’s agreement. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Dental Materials Journal 2016/01/29, Vol.35(1), pp.63-69
Hauptverfasser: IGIEL, Christopher, WEYHRAUCH, Michael, WENTASCHEK, Stefan, SCHELLER, Herbert, LEHMANN, Karl Martin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to compare the agreement rate (%) and color difference (ΔE*ab) of three dental color-measuring devices, with the visual shade identification. The tooth color were determined by two operators, which were advised to select a VITA classic shade tab in each other’s agreement. The Shadepilot (SP), CrystalEye (CE) and ShadeVision (SV) were used to measure tooth color. Statistically analyses include agreement rate (%), color difference (ΔE*ab), McNemar test (p=0.05), Student’s t-test (p=0.05) and Bland Altman scatterplots. The SP had an agreement of 56.3% with the visual shade determination, the CE 49.0% and SV 51.3%. ΔE*ab of the visually and instrumentally selected shade tabs and natural teeth were frequently above the threshold for acceptability. Comparing both methods, for SP ΔE*ab values differ in a range of clinical acceptability.
ISSN:0287-4547
1881-1361
DOI:10.4012/dmj.2015-006