NUMERICAL SIMULATION OF FILM COOLING OVER FLAT PLATE
The effect of film cooling over flat plate is investigated using the commercial CD code; Fluent 6.3. The computational domain includes the coolant supply tube as well as the main mixing region. A tube L/D of 4 and injection angles of (30[degrees], 60[degrees], and 90[degrees]) were employed for blow...
Gespeichert in:
Veröffentlicht in: | ARPN journal of engineering and applied sciences 2015-04, Vol.10 (6), p.2518-2522 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The effect of film cooling over flat plate is investigated using the commercial CD code; Fluent 6.3. The computational domain includes the coolant supply tube as well as the main mixing region. A tube L/D of 4 and injection angles of (30[degrees], 60[degrees], and 90[degrees]) were employed for blowing ratio of (0.33, 0.5, and 1.67), and a density ratio of 1.14. Adiabatic film cooling effectiveness distributions were also determined for inline and staggered arrangements. The main observation from this study that the 30[degrees] hole gave larger effectiveness values than 60[degrees] and 90[degrees] at the blowing ratio of 0.33 with the same length-to-diameter ratio. The maximum effectiveness was achieved with a blowing ratio of 0.5. The results show that the increase of blowing ratio negatively affects film cooling, such that for the blowing ratio of 1.67 the injected coolant tends to lift off from the wall due to the increase of the wall normal momentum. The comparisons for numerical results with experimental data are presented. |
---|---|
ISSN: | 1819-6608 1819-6608 |