Laser-induced Breakdown Spectroscopy and ablation threshold analysis using a megahertz Yb fiber laser oscillator

A LIBS system is demonstrated using a 100m cavity Yb fiber oscillator producing ~70ps, 320nJ clusters of 50–100fs sub-pulses at 2MHz. A new empirical model for femtosecond ablation is presented to explain the LIBS signal intensity's non-linear dependence on pulse fluence by accounting for the G...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spectrochimica acta. Part B: Atomic spectroscopy 2015-05, Vol.107, p.146-151
Hauptverfasser: Parker, Gregory J., Parker, Daniel E., Nie, Bai, Lozovoy, Vadim, Dantus, Marcos
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A LIBS system is demonstrated using a 100m cavity Yb fiber oscillator producing ~70ps, 320nJ clusters of 50–100fs sub-pulses at 2MHz. A new empirical model for femtosecond ablation is presented to explain the LIBS signal intensity's non-linear dependence on pulse fluence by accounting for the Gaussian beam's spatial distribution. This model is compared to experimental data and found to be superior to linear threshold fits. This model is then used to measure the ablation threshold of Cu using a typical amplified Ti:sapphire system, and found to reproduce previously reported values to within ~20%. The ablation threshold of Cu using the Yb fiber oscillator system was measured to be five times lower than on the amplified Ti:sapphire system. This effect is attributed to the formation of nanostructures on the surface, which have previously been shown to decrease the ablation threshold. The plasma lifetime is found to be ~1ns, much shorter than that of nanosecond ablation, further indicating that the decreased threshold results from surface effects rather than laser–plasma interaction. The low threshold and high pulse energy of the Yb fiber oscillator allows the acquisition of LIBS spectra at megahertz repetition rates. This system could potentially be developed into a compact, fiber-based portable LIBS device taking advantage of the benefits of ultrafast pulses and high repetition rates. •We performed LIBS using a unique ultrafast fiber laser oscillator producing clusters of femtosecond pulses at 2MHz.•We found the LIBS threshold to be lower than the ablation threshold for single femtosecond laser pulses.•We introduce a model for the LIBS threshold that leads to more accurate determination of threshold values.•We provide results for a number of different solid samples.•The new setup could lead to the design of very compact (portable) and femtosecond-LIBS setups.
ISSN:0584-8547
1873-3565