Internal insulation applied in heritage multi-storey buildings with wooden beams embedded in solid masonry brick façades
The use of internal insulation is investigated in a heritage building block with wooden beam construction and masonry brick walls as part of an energy renovation. Measurements were carried out and compared to results from a hygrothermal simulation model. The risk of mould growth in the wooden beams...
Gespeichert in:
Veröffentlicht in: | Building and environment 2016-04, Vol.99, p.59-72 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The use of internal insulation is investigated in a heritage building block with wooden beam construction and masonry brick walls as part of an energy renovation. Measurements were carried out and compared to results from a hygrothermal simulation model. The risk of mould growth in the wooden beams and in the interface between the insulation and the brick wall was evaluated. Three different insulation strategies for applying internal insulation were investigated: 1) insulation applied on the entire interior façade; 2) 200 mm gap in the insulation above the floor; and 3) 200 mm gap in the insulation both above the floor and below the ceiling. The solution with a 200 mm gap in the insulation above and below the floor/ceiling showed that at low rain exposure coefficients (Catch Ratio, CR ≤ 0.1) and with wall orientations towards west, this solution can be moisture-safe. However, it not recommended to apply internal insulation on north-orientated walls, since the drying potential is reduced. Additionally, caution should be exercised also with west-orientated walls.
•We energy renovated an old heritage multi-storey building with internal insulation.•We examined the moisture safety of different internal insulation strategies.•Full-scale measurements and numerical simulations on hygrothermal performance.•Α 200 mm gap in the insulation can be moisture safe solution for some orientations.•It is not recommended to apply internal insulation at thin walls towards north. |
---|---|
ISSN: | 0360-1323 1873-684X |
DOI: | 10.1016/j.buildenv.2016.01.019 |