Coupler conditioning and high power testing of ADS Spoke cavity

Power couplers, used in China-ADS proton linac injector I, are required to transfer 6 kW RF power to the superconducting Spoke cavities. At present, first the two couplers of a coaxial design have been fabricated, which accomplished a high power test at IHEP. The test results indicated that couplers...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese physics C 2014-02, Vol.38 (2), p.67-69
1. Verfasser: 陈旭 孟繁博 马强 黄彤明 林海英 潘卫民
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Power couplers, used in China-ADS proton linac injector I, are required to transfer 6 kW RF power to the superconducting Spoke cavities. At present, first the two couplers of a coaxial design have been fabricated, which accomplished a high power test at IHEP. The test results indicated that couplers of this design are qualified to deliver 10 kW RF power in continuous travelling wave mode. This paper describes the coupler's room temperature test procedures and results and discusses the original high power test, which was terminated due to serious out-gassing and after some modifications. In the final test, the couplers smoothly exceeded the design power level.
ISSN:1674-1137
0254-3052
DOI:10.1088/1674-1137/38/2/027001