Measurement of the fluorescence quantum yield of bis-MSB
The fluorescence quantum yield of bis-MSB, a widely used liquid scintillator wavelength shifter, was measured to study the photon absorption and re-emission processes in a liquid scintillator. The re-emission process affects the photoelectron yield and distribution, especially in a large liquid scin...
Gespeichert in:
Veröffentlicht in: | Chinese physics C 2015-12, Vol.39 (12), p.44-50 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The fluorescence quantum yield of bis-MSB, a widely used liquid scintillator wavelength shifter, was measured to study the photon absorption and re-emission processes in a liquid scintillator. The re-emission process affects the photoelectron yield and distribution, especially in a large liquid scintillator detector, thus must be under- stood to optimize the liquid scintillator for good energy resolution and to precisely simulate the detector with Monte Carlo. In this study, solutions of different bis-MSB concentration were prepared for absorption and fluorescence emission measurements to cover a broad range of wavelengths. Harmane was used as a standard reference to obtain the absolution fluorescence quantum yield. For the first time we measured the fluorescence quantum yield of bis-MSB up to 430 nm as inputs required by Monte Carlo simulation, which is 0.926±0.053 at ;λex=350 nm. |
---|---|
ISSN: | 1674-1137 0254-3052 |
DOI: | 10.1088/1674-1137/39/12/126001 |