Numerical simulation and design optimization of an electrohydrodynamic pump for dielectric liquids

•We firstly demonstrated that optimized set of parameters exists in the design of an electrohydrodynamic(EHD) pump.•We applied recently developed techniques of optimization to the EHD pump composed of a pair of flat plates and one circular cylinder.•Our work serves as driving knowledge for the resea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The International journal of heat and fluid flow 2016-02, Vol.57, p.1-10
Hauptverfasser: Fernandes, D.V., Suh, Y.K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•We firstly demonstrated that optimized set of parameters exists in the design of an electrohydrodynamic(EHD) pump.•We applied recently developed techniques of optimization to the EHD pump composed of a pair of flat plates and one circular cylinder.•Our work serves as driving knowledge for the research area on EHD pumping. With an ever increasing demand for more effective heat sinks, liquid based electronic cooling has become a new prospect in the field. The present study introduces an electrohydrodynamic (EHD) pump with a simple design for dielectric liquids which have potential applications for electronic cooling. The pump consists of an eccentrically sandwiched wire electrode placed at the horizontal centerline between two parallel flat-plate electrodes. The EHD flow of dielectric liquid induced by the space charge generated due to the Onsager effect was obtained by the numerical solution of the Poisson–Nernst–Planck equations for ion transport and the Navier–Stokes equations for fluid flow. Good agreement obtained in the comparison of the numerical and the experimental results of velocity for the centrally sandwiched wire electrode case confirmed the validity of the numerical results. For a fixed voltage, the pump flow rate depends on the eccentricity of the wire electrode with respect to the plate electrodes and also with the electrode dimensions. By using the Taguchi method an optimum design for the EHD pump is obtained considering the wire electrode diameter, the flat plate electrode length and the eccentricity (the horizontal distance between the centers of wire and flat-plate electrodes) as the design parameters for fixed channel dimensions.
ISSN:0142-727X
1879-2278