A systematic review of diagnostic accuracy of vertebral fracture assessment (VFA) in postmenopausal women and elderly men

Summary This systematic review was performed to compare the diagnostic accuracy of vertebral fracture assessment (VFA) with that of spinal radiography for identification of vertebral fractures (VFs). VFA appeared to have moderate sensitivity and high specificity for detecting VFs when compared with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Osteoporosis international 2016-05, Vol.27 (5), p.1691-1699
Hauptverfasser: Lee, J.-H., Lee, Y. K., Oh, S.-H., Ahn, J., Lee, Y. E., Pyo, J. H., Choi, Y. Y., Kim, D., Bae, S.-C., Sung, Y.-K., Kim, D.-Y.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Summary This systematic review was performed to compare the diagnostic accuracy of vertebral fracture assessment (VFA) with that of spinal radiography for identification of vertebral fractures (VFs). VFA appeared to have moderate sensitivity and high specificity for detecting VFs when compared with spinal radiography. Introduction VFs are recognized as the hallmark of osteoporosis, and a previous VF increases the risk of a future fracture. Therefore, the timely detection of VFs is important for prevention of further fractures. This systematic review examined the diagnostic accuracy of VFA using dual X-ray absorptiometry (DXA) to identify VFs. Methods We searched for potentially relevant studies using electronic databases, including Ovid-Medline, Ovid-EMBASE, Cochrane library, and four Korean databases, from their inception to May 2013. We compared the diagnostic accuracy of VFA with that of spinal radiography for detection of VFs by analyzing the sensitivity and specificity using a 2 × 2 contingency table. Subgroup analyses were also performed on studies with a low risk of bias and applicability. Results Twelve studies were analyzed for the diagnostic accuracy of VFA. The sensitivity and specificity were 0.70–0.93 and 0.95–1.00, respectively, analyzed on a per-vertebra basis, and 0.65–1.00 and 0.74–1.00 on a per-patient basis. The sensitivity and specificity of five studies in subgroups with a low risk of bias in the intervention test were 0.70–0.84 and 0.96–0.99, respectively. In studies with a low risk of bias in the patient selection, those based on a per-vertebra basis in three studies were 0.70–0.93 and 0.96–1.00, respectively. Conclusions VFA had moderate sensitivity and high specificity for detecting VF when compared with spinal radiography. However, the present findings are insufficient to assess whether spinal radiography should be replaced by VFA.
ISSN:0937-941X
1433-2965
DOI:10.1007/s00198-015-3436-z