HPLC Method for Determination of Atenolol in Human Plasma and Application to a Pharmacokinetic Study in Turkey

This paper describes a high-performance liquid chromatography method for the determination of atenolol in human plasma. Atenolol and the internal standard, metoprolol, were extracted from plasma by using a liquid-liquid extraction method. The method was developed on an Ace C18 reverse-phase column u...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatographic science 2012-11, Vol.50 (10), p.914-919
Hauptverfasser: Yilmaz, Bilal, Arslan, Sakir, Asci, Ali
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper describes a high-performance liquid chromatography method for the determination of atenolol in human plasma. Atenolol and the internal standard, metoprolol, were extracted from plasma by using a liquid-liquid extraction method. The method was developed on an Ace C18 reverse-phase column using a mobile phase of methanol-water (50:50, v/v) containing 0.1% trifluoroacetic acid. The calibration curve was linear within the concentration range of 5-150 ng/mL. Intra-day and inter-day precision values for atenolol in plasma were less than 6.1, and accuracy (relative error) was better than 5.5%. The mean recovery of atenolol was 98.4% for plasma. The limits of detection and quantification of atenolol were 1.5 and 5 ng/mL, respectively. Also, this assay was successfully applied to six patients with hypertension who had been given an oral tablet of 50 mg atenolol.
ISSN:0021-9665
1945-239X
DOI:10.1093/chromsci/bms090