Long-Term Outcomes for Patients With Severe Symptomatic Aortic Stenosis Treated With Transcatheter Aortic Valve Implantation

Transcatheter aortic valve implantation (TAVI) is an established technique for the treatment of severe symptomatic aortic stenosis. Data on long-term TAVI outcomes, both hemodynamic and clinical, in real-world practice settings are limited. We aim to explore the long-term clinical results in patient...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of cardiology 2015-11, Vol.116 (9), p.1391-1398
Hauptverfasser: Codner, Pablo, MD, Orvin, Katia, MD, Assali, Abid, MD, Sharony, Ram, MD, Vaknin-Assa, Hanna, MD, Shapira, Yaron, MD, Schwartzenberg, Shmuel, MD, Bental, Tamir, MD, Sagie, Alexander, MD, Kornowski, Ran, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Transcatheter aortic valve implantation (TAVI) is an established technique for the treatment of severe symptomatic aortic stenosis. Data on long-term TAVI outcomes, both hemodynamic and clinical, in real-world practice settings are limited. We aim to explore the long-term clinical results in patients with severe symptomatic aortic stenosis using multiple catheter-based options: 360 TAVI-treated patients were followed up for ≤5 years. The Medtronic CoreValve was used in 71% and the Edwards SAPIEN in 26%. The primary end point was all-cause mortality during follow-up. Outcomes were assessed based on the Valve Academic Research Consortium 2 criteria. The mean ± SD patient age was 82.1 ± 6.9 years (56.4% women). The Society of Thoracic Surgeons score was 7.5 ± 4.7. The clinical efficacy end point and time-related valve safety at 3 years was 50% and 81.7%, respectively. The calculated 3- and 5-year survival rates were 71.6% and 56.4%, respectively. Five-year follow-up data were obtained for 54 patients alive; 96.2% of alive patients were in the New York Heart Association class I and II, 4 years after TAVI. No gender differences in all-cause mortality rates were observed (p = 0.58). In multivariate analysis, hospitalization 6 months previous to TAVI (hazard ratio [HR] 1.92, 95% confidence interval [CI] 1.17 to 3.15, p = 0.01), frailty (HR 1.89, 95% CI 1.11 to 3.2, p = 0.02), acute kidney injury (HR 1.93, 95% CI 1.03 to 3.61, p = 0.04), and moderate or more paravalvular aortic regurgitation after TAVI (HR 4.26, 95% CI 2.54 to 7.15, p
ISSN:0002-9149
1879-1913
DOI:10.1016/j.amjcard.2015.08.004